Comparative Analysis of Dimensional Precision of Different Silicone Impression Materials
Authors:
- Mohamed G SughaireenMSMohamed G Sughaireen
- 1 June 2011
- journal article
- research article
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 12 (3) , 208-215
Abstract
Objectives: To investigate the accuracy of four commercial types of additional silicone impression materials (AFFINIS®, Virtual®, Relay 2002 CD® and Silagum®). Materials and methods: The accuracy of impression material was measured indirectly by measuring three dimensions on stone cast poured from impressions of a stainless steel master model. The three dimensions on stone cast were measured at 1 hour, 2 days, 1 and 2 weeks after making the impression. Two impression techniques were used in the current study. The two-step impression technique was used for AFFINIS® and Virtual®, while single-step technique was used for Relay 2002 CD® and Silagum® materials. Twenty impressions were made of the master cast at four different periods for each of the tested four materials with a total of 320 impressions. Two vertical dimensions and one horizontal dimension were measured on master cast using optical microscope. Statistical analysis was run to compare the mean measurements for tested casts from each impression and time interval with the master cast. Results: No statistical significant differences were found (p > 0.05) in the accuracy of tested materials. There was no significant difference of master cast and impression cast means over time. Additionally, impression technique could be correlated with accuracy. Conclusion: The tested additional silicones showed accuracy over time and they could be delayed up to 4 weeks duration without any significant changes in its dimensional stability. Silagum® impression material was the most accurate followed by Relay 2002 CD®, Virtual® and AFFINIS®. Clinical significance: Silagum® impression material is most accurate followed by Relay 2002 CD®, Virtual® and AFFINIS®. How to cite this article: Al-Zarea BK, Sughaireen MG. Comparative Analysis of Dimensional Precision of Different Silicone Impression Materials. J Contemp Dent Pract 2011; 12(3):208-215.Keywords
This publication has 20 references indexed in Scilit:
- Dimensional accuracy of dental casts: Influence of tray material, impression material, and timeJournal of Prosthodontics, 2002
- Comparison of the dimensional accuracy of one- and two-step techniques with the use of putty/wash addition silicone impression materialsThe Journal of Prosthetic Dentistry, 1995
- Comparative elasticity tests for elastomeric (non putty) impression materialsAustralian Dental Journal, 1992
- Accuracy of one-step versus two-step putty wash addition silicone impression techniqueThe Journal of Prosthetic Dentistry, 1992
- Distortion analysis of stone casts made from impression materialsThe Journal of Prosthetic Dentistry, 1985
- Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of modelsThe Journal of Prosthetic Dentistry, 1985
- An evaluation of the time-dependent dimensional stability of eleven elastomeric impression materialsThe Journal of Prosthetic Dentistry, 1984
- Long‐term dimensional stability of three current elastomersJournal of Oral Rehabilitation, 1983
- Thermal expansion of addition polymerization (Type II) silicone impression materials*Australian Dental Journal, 1982
- Addition curing silicone rubber impression materials. An appraisal of their physical propertiesBritish Dental Journal, 1978