Abstract
Aim of the study was to evaluate the precise influence of different intrahepatic vessels, vessel sizes, and distances from the applicator on volume and shape of hepatic laser ablation zones in an in vivo porcine model. The study was approved by the institutional animal care and use committee. Eighteen computed tomography-guided Nd:YAG laser ablations were performed in the livers of 10 pigs at varying distances from hepatic veins and portal fields. After hepatectomy the livers were cut into 2-mm slices perpendicular to the laser applicator axes. For each ablation zone the maximum achievable (ideal) volume, the segmented (real) volume, the maximum radius, and the radius at the position of adjacent hepatic vessels were determined. The shapes of the ablation zones were evaluated qualitatively. Comparative statistics using the unpaired t test and a multiple linear regression analysis were performed. Ideal and real ablation zone volumes differed by 27.3% (8.6 +/- 1.5 mL vs. 6.4 +/- 1.1 mL; P < 0.0001). Thirty-eight of 60 (63%) hepatic veins versus 28 of 31 (90%) portal veins within the central slices of the 18 ablation zones led to a reduction of the ablation zone's radius, depending on the distance between the vessel and the applicator and the vessel type. Portal fields revealed stronger effects than hepatic veins. The vessel diameter showed no independent effect (P > 0.05). When influencing, all hepatic veins showed a focal indentation whereas portal fields always showed broad flattening of the ablation zone. Portal fields lead to more heat sink than hepatic veins. The effects decreased with the distance between vessel and applicator tip, but less so for portal fields. The 2 vessel types induced considerably different shape alterations of the ablation zones. These results were not dependent on vessel size. This should be considered in the planning of thermal tumor ablations.Keywords
This publication has 26 references indexed in Scilit:
- Experimental Radiofrequency Ablation Near the Portal and the Hepatic Veins in Pigs: Differences in Efficacy of a Monopolar Ablation SystemJournal of Surgical Research, 2006
- Analysis of factors predicting survival in patients with hepatocellular carcinoma treated with percutaneous laser ablationJournal of Hepatology, 2006
- Percutaneous laser ablation in patients with isolated unresectable liver metastases from colorectal cancer: Results of a phase II studyActa Oncologica, 2006
- Local Recurrence After Hepatic Radiofrequency CoagulationAnnals of Surgery, 2005
- Radiofrequency Ablation of Hepatocellular Carcinoma: Treatment Success as Defined by Histologic Examination of the Explanted LiverRadiology, 2005
- Comparison of resection and radiofrequency ablation for treatment of solitary colorectal liver metastasesBritish Journal of Surgery, 2003
- Effect of Vascular Occlusion on Radiofrequency Ablation of the LiverAmerican Journal of Roentgenology, 2001
- MR-guided interstitial laser-induced thermotherapy of hepatic metastasis combined with arterial blood flow reduction: Technique and first clinical results in an open MR systemJournal of Magnetic Resonance Imaging, 2001
- Radiofrequency Ablation of Porcine Liver In VivoAnnals of Surgery, 1998
- Percutaneous Radiofrequency Tissue Ablation: Does Perfusion-mediated Tissue Cooling Limit Coagulation Necrosis?Journal of Vascular and Interventional Radiology, 1998