Surface modification strategies for hemodialysis catheters to prevent catheter‐related infections: A review
Authors:
- 31 August 2020
- journal article
- review article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (3) , 314-327
Abstract
Insertion of a central venous catheter is one of the most common invasive procedures applied in hemodialysis therapy for end‐stage renal disease. The most important complication of a central venous catheter is catheter‐related infections that increase hospitalization and duration of intensive care unit stay, cost of treatment, mortality, and morbidity rates. Pathogenic microorganisms, such as, bacteria and fungi, enter the body from the catheter insertion site and the surface of the catheter can become colonized. The exopolysaccharide‐based biofilms from bacterial colonies on the surface are the main challenge in the treatment of infections. Catheter lock solutions and systemic antibiotic treatment, which are commonly used in the treatment of hemodialysis catheter‐related infections, are insufficient to prevent and terminate the infections and eventually the catheter needs to be replaced. The inadequacy of these approaches in termination and prevention of infection revealed the necessity of coating of hemodialysis catheters with bactericidal and/or antiadhesive agents. Silver compounds and nanoparticles, anticoagulants (e.g., heparin), antibiotics (e.g., gentamicin and chlorhexidine) are some of the agents used for this purpose. The effectiveness of few commercial hemodialysis catheters that were coated with antibacterial agents has been tested in clinical trials against catheter‐related infections of pathogenic bacteria, such as Staphylococcus aureus and Staphylococcus epidermidis with promising results. Novel biomedical materials and engineering techniques, such as, surface micro/nano patterning and the conjugation of antimicrobial peptides, enzymes, metallic cations, and hydrophilic polymers (e.g., poly [ethylene glycol]) on the surface, has been suggested recently.Keywords
This publication has 122 references indexed in Scilit:
- Reducing the risk of infection associated with vascular access devices through nanotechnology: a perspectiveInternational Journal of Nanomedicine, 2013
- An Organoselenium Compound Inhibits Staphylococcus aureus Biofilms on Hemodialysis Catheters In VivoAntimicrobial Agents and Chemotherapy, 2012
- Vascular Access Sites for Acute Renal Replacement in Intensive Care UnitsClinical Journal of the American Society of Nephrology, 2012
- Minocycline-EDTA Lock Solution Prevents Catheter-Related Bacteremia in HemodialysisJournal of the American Society of Nephrology, 2011
- The Spectrum of Infections in Catheter-Dependent Hemodialysis PatientsClinical Journal of the American Society of Nephrology, 2011
- Guidelines for the Prevention of Intravascular Catheter-related InfectionsClinical Infectious Diseases, 2011
- New materials and devices for preventing catheter-related infectionsAnnals of Intensive Care, 2011
- Bismuth coating of non-tunneled haemodialysis catheters reduces bacterial colonization: a randomized controlled trialNephrology Dialysis Transplantation, 2010
- Does Heparin Coating Improve Patency or Reduce Infection of Tunneled Dialysis Catheters?Clinical Journal of the American Society of Nephrology, 2009
- A Review of Evolving Dialysis Catheter TechnologiesSeminars in Interventional Radiology, 2009