Optimum multiple tuned mass dampers for structures under the ground acceleration based on the uniform distribution of system parameters
Authors:
- 31 January 2003
- journal article
- research article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 32 (5) , 671-690
Abstract
The five MTMD models, with natural frequencies being uniformly distributed around their mean frequency, have been recently presented by the first author. They are shown to have the near‐zero optimum average damping ratio (more precisely, for a given mass ratio there is an upper limit on the total number, beyond which the near‐zero optimum average damping ratio occurs). In this paper, the eight new MTMD models (i.e. the UM‐MTMD1∼UM‐MTMD3, US‐MTMD1∼US‐MTMD3, UD‐MTMD1 and UD‐MTMD2), with the system parameters (mass, stiffness and damping coefficient) being, respectively, uniformly distributed around their average values, have been, for the first time here, proposed to seek for the MTMD models without the near‐zero optimum average damping ratio. The structure is represented by the mode‐generalized system corresponding to the specific vibration mode that needs to be controlled. Through minimization of the minimum values of the maximum dynamic magnification factors (DMF) of the structure with the eight MTMD models (i.e. through the implementation of Min.Min.Max.DMF), the optimum parameters and values of Min.Min.Max.DMF for these eight MTMD models are investigated to evaluate and compare their control performance. The optimum parameters include the optimum mass spacing, stiffness spacing, damping coefficient spacing, frequency spacing, average damping ratio and tuning frequency ratio. The six MTMD models without the near‐zero optimum average damping ratio (i.e. the UM‐MTMD1∼UM‐MTMD3, US‐MTMD1, US‐MTMD2 and UD‐MTMD2) are found through extensive numerical analyses. Likewise, the optimum UM‐MTMD3 offers the higher effectiveness and robustness and requires the smaller damping with respect to the rest of the MTMD models in reducing the responses of structures subjected to earthquakes. Additionally, it is interesting to note, by comparing the optimum UM‐MTMD3 with the optimum MTMD‐1 recently investigated by the first author, that the effectiveness and robustness for the optimum UM‐MTMD3 is almost identical to that for the optimum MTMD‐1 (without inclusion of the optimum MTMD‐1 with the near‐zero optimum average damping ratio). Recognizing these performance benefits, it is preferable to employ the optimum UM‐MTMD3 or the optimum MTMD‐1 without the near‐zero optimum average damping ratio, when installing the MTMD for the suppression of undesirable oscillations of structures under earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 8 references indexed in Scilit:
- Optimum multiple tuned mass dampers for structures under the ground acceleration based on DDMF and ADMFEarthquake Engineering & Structural Dynamics, 2002
- Performance of multiple tuned mass dampers for attenuating undesirable oscillations of structures under the ground accelerationEarthquake Engineering & Structural Dynamics, 2000
- Dynamic characteristics of structures with multiple tuned mass dampersSTRUCTURAL ENGINEERING AND MECHANICS, 1995
- Performance of Multiple Mass Dampers under Random LoadingJournal of Structural Engineering, 1995
- Tuned mass dampers for structures with closely spaced natural frequenciesEarthquake Engineering & Structural Dynamics, 1995
- Dynamic characterization of multiple tuned mass dampers and some design formulasEarthquake Engineering & Structural Dynamics, 1994
- Fundamental characteristics of Multiple Tuned Mass Dampers for suppressing harmonically forced oscillationsEarthquake Engineering & Structural Dynamics, 1993
- Dynamic characteristics of multiple substructures with closely spaced frequenciesEarthquake Engineering & Structural Dynamics, 1992