A Microassembled Low-Profile Three-Dimensional Microelectrode Array for Neural Prosthesis Applications
Authors:
- 8 August 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 16 (4) , 977-988
Abstract
This paper describes the design and micro- assembly process of a low-profile 3-D microelectrode array for mapping the functional organization of targeted areas of the central nervous system and for possible application in neural prostheses. The array consists of multiple planar complimentary metal-oxide-semiconductor stimulating probes and 3-D assembly components. Parylene-encapsulated gold beams supported by etch-stopped silicon braces allow the backends of the probes to be folded over to reduce the height of the array above the cortical surface. A process permitting parylene to be used at wafer level with bulk-silicon wet release has been reported. Spacers are used to fix the microassembled probes in position and are equipped with interlocking structures to facilitate the assembly process and increase yield. Four-probe 256-site 3-D arrays operate from plusmn5 V with an average per-channel power dissipation of 97 muW at full range stimulation with pulse widths of 100 mus at 500-Hz frequency. Thirty-two sites can be stimulated simultaneously with maximum currents of plusmn127 muA and a current resolution of plusmn1 muA. The microassembly techniques allow a variety of 3-D microstructures to be created from planar components.Keywords
This publication has 24 references indexed in Scilit:
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005
- Microelectrode Array Fabrication by Electrical Discharge Machining and Chemical EtchingIEEE Transactions on Biomedical Engineering, 2004
- An improved TMAH Si-etching solution without attacking exposed aluminum2002
- Flexible polyimide-based intracortical electrode arrays with bioactive capabilityIEEE Transactions on Biomedical Engineering, 2001
- Single-unit neural recording with active microelectrode arraysIEEE Transactions on Biomedical Engineering, 2001
- A 64-site multishank CMOS low-profile neural stimulating probeIEEE Journal of Solid-State Circuits, 1996
- A glass/silicon composite intracortical electrode arrayAnnals of Biomedical Engineering, 1992
- A method for pneumatically inserting an array of penetrating electrodes into cortical tissueAnnals of Biomedical Engineering, 1992
- Performance of planar multisite microprobes in recording extracellular single-unit intracortical activityIEEE Transactions on Biomedical Engineering, 1988
- SOMATIC MOTOR AND SENSORY REPRESENTATION IN THE CEREBRAL CORTEX OF MAN AS STUDIED BY ELECTRICAL STIMULATIONBrain, 1937