Equivalence of generalized state-space averaging with DQ modelling methods in a balanced three-phase system
- 1 September 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 5519-5524
Abstract
In most modern power electronics systems constant power loads (CPL) exist, which could have a severe influence on system stability. Conventionally two modelling tools for a system qualitative study are considered - generalized state-space averaging (GSSA) and DQ modelling methods. In this paper their strict mathematical equivalence in the balanced three-phase system is shown and areas of GSSA application are discussed. Experimental and simulation results comparing the switched model and the experiment results together with the comparison of the switched model and the GSSA and DQ models are also presented.Keywords
This publication has 7 references indexed in Scilit:
- Power Electronic Converters Modeling and Control2014
- Aircraft Power System Stability Study Including Effect of Voltage Control and Actuators DynamicIEEE Transactions on Aerospace and Electronic Systems, 2011
- Small-Signal Methods for AC Distributed Power Systems–A ReviewIEEE Transactions on Power Electronics, 2009
- DQ-transformation approach for modelling and stability analysis of AC-DC power system with controlled PWM rectifier and constant power loads2008
- Stability analysis and modelling of AC-DC system with mixed load using DQ-transformation method2008
- State-space average modelling of 6- and 12-pulse diode rectifiers2007
- Modeling of Power Electronic Loads in AC Distribution Systems Using the Generalized State-Space Averaging MethodIEEE Transactions on Industrial Electronics, 2004