A Cylindrical-Core Fiber-Optic Oxygen Sensor Based on Fluorescence Quenching of a Platinum Complex Immobilized in a Polymer Matrix
Authors:
- 28 March 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 12 (1) , 71-75
Abstract
A miniature (200 μm in diameter) cylindrical-core fiber-optic oxygen sensor has been developed for measuring rapid change in oxygen partial pressure (pO2). The fiber-optic sensing element is based on a cylindrical-core waveguide structure formed by coating a thin medical grade polymer sensing film that contains immobilized Pt(II) complexes on silica optical fiber. The performance such as sensitivity and time response of the fiber-optic oxygen sensors were evaluated using luminescence intensity measurement. To determine accurately the response time of the fiber optic oxygen sensors, a test chamber was used to provide rapid changes in the partial pressure of oxygen. The result showed that the time response (time-constant, τ) of this cylindrical-core fiber optic oxygen sensor is less than 50 ms. To our knowledge, this is the fastest such sensor of this size covering the full dynamic range of pO2 from 0 to 100 kPa.Keywords
This publication has 18 references indexed in Scilit:
- Optical fiber dissolved oxygen sensor based on Pt(II) complex and core-shell silica nanoparticles incorporated with sol–gel matrixSensors and Actuators B: Chemical, 2010
- A fiber-optic evanescent wave sensor for dissolved oxygen detection based on novel hybrid fluorinated xerogels immobilized with [Ru(bpy)3]2+Analytical and Bioanalytical Chemistry, 2009
- Ratiometric fiber-optic oxygen sensors based on sol–gel matrix doped with metalloporphyrin and 7-amino-4-trifluoromethyl coumarinSensors and Actuators B: Chemical, 2008
- Temperature compensation of fluorescence intensity-based fiber-optic oxygen sensors using modified Stern–Volmer modelSensors and Actuators B: Chemical, 2008
- High-performance fiber-optic oxygen sensors based on fluorinated xerogels doped with Pt(II) complexesSensors and Actuators B: Chemical, 2007
- Single standard calibration for an optical oxygen sensor based on luminescence quenching of a ruthenium complexAnalytica Chimica Acta, 2000
- Peer Reviewed: Oxygen Sensors Based on Luminescence Quenching.Analytical Chemistry, 1999
- Coherent atomic waveguides from hollow optical fibers: Quantized atomic motionPhysical Review A, 1994
- Fibre optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol–gel derived porous coatingsThe Analyst, 1993
- Optical characteristics of a ruthenium(II) complex immobilized in a silicone rubber film for oxygen measurementThe Analyst, 1993