Imaging targeted-agent binding in vivo with two probes
Authors:
- Brian W. PogueBPBrian W. Pogue
- Kimberley S. SamkoeKSKimberley S. Samkoe
- Michael JermynMJMichael Jermyn
- Tayyaba HasanTHTayyaba Hasan
Open Access
- 1 January 2010
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 15 (3) , 030513-3
Abstract
An approach to quantitatively image targeted-agent binding rate in vivo is demonstrated with dual-probe injection of both targeted and nontargeted fluorescent dyes. Images of a binding rate constant are created that reveal lower than expected uptake of epidermal growth factor in an orthotopic xenograft pancreas tumor (2.3×10−5 s−1), as compared to the normal pancreas (3.4×10−5 s−1). This approach allows noninvasive assessment of tumor receptor targeting in vivo to determine the expected contrast, spatial localization, and efficacy in therapeutic agent delivery. Targeting therapeutic drugs to tumors based on their overexpression of cellular receptors is widely researched and has important clinical success.1, 2 Yet there are essentially no good tools to assess the in vivo receptor expression contrast between tumor as compared to normal surrounding tissue.3, 4 In tumors with very high molecular signaling such as in the pancreas,4, 5 it is not obvious when a particular receptor is actually up-regulated as compared to the surrounding normal tissue versus upregulated without biopsy. Imaging of receptor status in vivo is problematic, because the majority of any targeted agent in vivo is often not cell-associated yet. Thus, any single image simply provides a measure of the whole tissue concentration rather than the bound concentration. Delivery from the vascular supply to tumor cells requires transvascular leakage, followed by diffusion through the interstitial space, and binding to the targeted receptor followed by possible internalization.6 As such, imaging concentration values in vivo usually do not provide information about binding,7 since most of the agent is in the interstitial space. In this work, we demonstrate a new methodology for quantitative imaging of effective binding rate in vivo, using the difference in fluorescence signal between a targeted and untargeted agent. We use this to demonstrate that a tumor known to have high EGFR expression in vitro 5 actually has lower EGF activity than the surrounding normal pancreas in vivo. Most contrast agent imaging has been interpreted with a simple pharmacokinetic model that is designed with as few compartments and rate constants as possible to not overinterpret the data. A three compartment model [Fig. 1 ] can be used effectively to model targeted agent delivery in the tumor, which includes compartments for 1. the concentration of drug in the plasma within the vasculature, 2. the concentration in the interstitial space of the tissue, and 3. the cellular-associated fraction of drug.7 The dominant fast rates in this model are transvascular delivery of contrast agent through rate constant , and then cell-associating rate constant due to binding and uptake, . The dominant clearance from the plasma is given by excretion mechanisms, such as those in the liver and kidneys, through rate constant . Then the slowest rates tend to be those involved in backflow from the interstitial space to the vasculature , and from the cell-associated space to the interstitial space . Each of these is shown in the illustration of the model in Fig. 1. <!-- named anchor --> Fig. 1 Compartment model is shown in (a), which includes all the main components of the tumor, including vascular , interstitial , and cellular-associated concentrations. The rate constants from transitions are shown along with volume fractions. In (b), an estimated table of values is shown for the pancreas and AsPC-1 xenograft tumor ( units are ). In (c), the rate equations were solved and concentrations for each compartment are plotted as a function of time. In (d), the concentrations for targeted and nontargeted dyes are shown to illustrate what the imaging data would show. Based on this linear model, and assuming that backflow from interstitial space to vasculature is negligible, the concentrations are related to each other with first-order rate equations: <!-- named anchor --> 1 <!-- named anchor --> 2 <!-- named anchor --> 3 Typical values of the concentrations are estimated by solving Eqs. 1, 2, 3 in Fig. 1 using estimates of the and values for the AsPC1 (pancreatic adenocarnioma) tumor. Using the simplified compartment model from before, the cell-association rate constant can potentially be estimated from the data of overall tissue concentration, given sufficient accuracy and observables. The problem in accurately estimating comes in the fact that the effect of is a subtle part of the overall curve, and it is not obvious that and can be independently estimated given a single temporal dataset. In fact, there is quite high sensitivity to , but considerably less sensitivity to .It is important to recognize that data from tissue does not exactly discriminate the individual compartments , , and from each other, as the imaging yields the total signal weighted by the relative volume fractions (where each is normalized such that ). For a specific targeted dye, which is planned to associate with the cellular fraction, the total tissue concentration, is given by the volume fractions multiplied by the concentration of each: <!-- named anchor --> 4 If a nonspecific imaging agent is used, it can be assumed that the cellular associated fraction is equal to zero, such that only plasma and interstitial fractions are seen and the tissue concentration is expressed by: <!-- named anchor --> 5 These can be used along with the values of , , and from before to estimate the expected bulk tissue concentrations, as shown in Fig. 1. In fact, the difference between the and values [Fig. 1] appears very close to the shape of the curve for the cellular-associated fraction [Fig. 1].Since the first term in each of these equations is low in the regions where there are low plasma volume (i.e., in bulk tissue without large vessels), then Eqs. 4, 5 become: <!-- named anchor --> 6 <!-- named anchor --> 7 Now from the rate model, some simple approximations can be used to estimate a value for . Under the assumption that , the latter term in Eq. 3 can be ignored, and then could be defined simply by integration as: <!-- named anchor --> 8 These equations lead to the following derivation using the observed data and : <!-- named anchor --> 9 Therefore, an estimate of the binding rate constant in vivo is possible given the signal processing on the left side of Eq. 9. Additionally, the observation that the difference between the targeted and nontargeted concentrations [Fig. 1] looks qualitatively like the cellular-associated fraction [Fig. 1] makes sense, since this is the numerator in this new Eq. 9.This nearly linear relationship means that imaging data can be used to estimate binding, if two dyes can be injected at the same time, and their fluorescence values used to calculate the ratio in Eq. 9. To reiterate, the key assumption here is that the vascular space effect on the signal is minimal, and the backflow is minimal. This first assumption means that this approximation will not hold where there are large plasma regions in images, but when volume averaged data are used and the is low, this approximation should be valid. The theoretical derivation in Eq. 9 is in terms of the concentrations of and , which are not directly measured. Instead, fluorescence is used, which is linearly proportional to them. In this dual-probe imaging, a key issue is to normalize for the difference in signal between the targeted and non targeted dye fluorescence values. As such, we introduce the following approximations, and , such that we can rewrite Eq. 9 in terms of the fluorescence intensity values: <!-- named anchor --> 10 where is defined as , the ratio of amplitude values that accounts for excitation/emission differences in the two agents as well as any collection efficiencies that are geometry-specific to the imaging system. This ratio therefore allows for cancellation of geometric/intensity effects that are common to both agent signals, and can be estimated by sampling signals from normal tissue. The estimate of from Eq. 10 can be done at any time point, so it is possible to get multiple estimates as a function of time. But simulations and data indicate that the estimate of converges to a value near in our case when a significant faction of the targeted dye is bound, allowing accurate difference estimation in the numerator.To test the ability to image directly, AsPC1 xenograft pancreas tumors were inoculated into mice and imaged in vivo. The tumors were used when they were a few millimeters in diameter, and an incision was created in the abdomen and the pancreas exposed for...
Keywords
This publication has 7 references indexed in Scilit:
- Consensus Report of the National Cancer Institute Clinical Trials Planning Meeting on Pancreas Cancer TreatmentJournal of Clinical Oncology, 2009
- Impact of tumor-specific targeting on the biodistribution and efficacy of siRNA nanoparticles measured by multimodality in vivo imagingProceedings of the National Academy of Sciences, 2007
- HER2/neu in systemic therapy for women with breast cancer: a systematic reviewBreast Cancer Research and Treatment, 2007
- Monoclonal antibody therapy of cancerNature Biotechnology, 2005
- Early detection markers in Pancreas CancerCancer Biomarkers, 2005
- Defining the role of the epidermal growth factor receptor in pancreatic cancer grown in vitroThe American Journal of Surgery, 2003
- Passive tumor targeting of soluble macromolecules and drug conjugates.1992