The Biomechanical Effect of Pedicle Screwsʼ Insertion Angle and Position on the Superior Adjacent Segment in 1 Segment Lumbar Fusion
- 1 September 2012
- journal article
- biomechanics
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (19) , 1637-1644
Abstract
Study Design. A finite element analysis. Objective. To investigate the association between the position of an inserted pedicle screw and the corresponding facet contact force or intradiscal pressure. Summary of Background Data. Although superior facet joint violation by pedicle screws is not an uncommon occurrence in instrumented lumbar fusion surgery, its actual biomechanical significance is not well understood. Furthermore, the association between the position of the pedicle screw and the stress on the corresponding disc/facet joint has yet to be investigated. Methods. According to the positions of pedicle screws in L4 of the L4–L5 lumbar fusion, 4 L4–L5 fusion models were simulated. These models included the violation of both L3–L4 superior facet joints by pedicle screws (facet joint violation [FV] model), the nonencroachment of both L3–L4 superior facet joints by pedicle screws (facet joint preservation [FP] model), and the removal state of pedicle screws in the FV model (removal of violated pedicle screws [rFV] model). The facet joint contact [FC] model represented the scenario in which the pedicle screws did not encroach upon either facet joint but were inserted close to the L3–L4 facet joint surface. Moreover, the uninstrumented fusion [UF] model represented the uninstrumented L4–L5 fusion. In each scenario, the intradiscal pressures and facet contact forces at the L2–L3 and L3–L4 segments were analyzed under extension and torsion moments. Results. The FV model yielded the greatest increases in facet contact force and intradiscal pressure at the L3–L4 segment under extension and torsion moments. Following the FV model, the increases in intradiscal pressure and facet contact force were the second highest in the FC model followed by the FP model. Furthermore, the rFV model represented prominent reductions of previously increased facet contact force and intradiscal pressure at the L3–L4 segment. Conclusion. In models of 1-segment lumbar fusion surgery, the positions of pedicle screws were closely linked with corresponding disc stresses and facet contact forces. However, even in cases of facet violation by pedicle screws, removal of the pedicle screw after fusion completion can reduce facet contract forces and disc stresses under both extension and torsional moments.Keywords
This publication has 27 references indexed in Scilit:
- Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysisMedical & Biological Engineering & Computing, 2010
- Comparison of mechanical motion profiles following instrumented fusion and non-instrumented fusion at the L4-5 segmentClinical & Investigative Medicine, 2009
- The Surgical Management of Degenerative Lumbar SpondylolisthesisSpine, 2007
- Computed Tomography Evaluation of Superior-Segment Facet-Joint Violation After Pedicle Instrumentation of the Lumbar Spine With a Midline Surgical ApproachSpine, 2006
- Complications Associated with Pedicle Screws*Journal of Bone and Joint Surgery, 1999
- Degenerative Lumbar Stenosis: Diagnosis and ManagementJournal of the American Academy of Orthopaedic Surgeons, 1999
- Comparative Study of the Incidence and Severity of Degenerative Change in the Transition Zones After Instrumented Versus Noninstrumented Fusions of the Lumbar SpineJournal of Spinal Disorders, 1999
- Stability of Posterior Spinal Instrumentation and Its Effects on Adjacent Motion Segments in the Lumbosacral SpineSpine, 1998
- 1997 Volvo Award Winner in Clinical StudiesSpine, 1997
- Complications of Lumbar Spinal Fusion with Transpedicular InstrumentationSpine, 1992