Visual recovery after vitrectomy for macular hole using 25‐gauge instruments
Authors:
Open Access
- 1 March 2008
- journal article
- Published by Wiley in Acta Ophthalmologica
- Vol. 86 (2) , 151-155
Abstract
: Purpose: To determine whether vitrectomy with 25‐gauge instruments contributes to better postoperative visual recovery after macular hole (MH) surgery.Methods: The medical records for 46 consecutive eyes operated for MH by a single surgeon were retrospectively examined. Vitrectomy had been performed with a 25‐gauge instrument in 23 eyes (25‐G group) and with a 20‐gauge instrument in 23 eyes (20‐G group). Postoperative visual acuity (VA) in logMAR (logarithm of the minimum angle of resolution) units after 1 week and 1, 3, 6, 9 and 12 months, operating time, and volume of intraocular irrigating fluid were compared between the two groups.Results: Mean preoperative logMAR VA was 0.72 in the 25‐G group and 0.68 in the 20‐G group (p = 0.282, unpaired t‐test). One week after surgery, VA was significantly better in the 25‐G group (0.40 ± 0.34) than in the 20‐G group (0.58 ± 0.30) (p = 0.020). This significant difference was maintained until 9 months after surgery, but was no longer evident at 12 months (p = 0.182). Operating time was significantly shorter in the 25‐G group (56 ± 16 mins) than in the 20‐G group (85 ± 28 mins) (p = 0.003, unpaired t‐test). The volume of intraocular irrigating fluid was significantly less in the 25‐G group (244 ± 72 ml) than in the 20‐G group (416 ± 113 ml) (p < 0.0001).Conclusions: The use of 25‐gauge vitrectomy instruments leads to better postoperative visual recovery following surgery for MH during the first 9 months, probably as a result of shorter surgical time and a lower volume of intraocular irrigating fluid.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of Visual Function After Epiretinal Membrane Removal by 20-Gauge and 25-Gauge VitrectomyAmerican Journal of Ophthalmology, 2006
- Longer-term Outcomes of Transconjunctival Sutureless 25-gauge VitrectomyAmerican Journal of Ophthalmology, 2005
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- INFLUENCE OF THE CANNULATED VITRECTOMY SYSTEM ON THE OCCURRENCE OF IATROGENIC SCLEROTOMY RETINAL TEARSRetina, 1997
- Visual Field Loss After Vitreous SurgeryArchives of Ophthalmology (1950), 1997
- Effect of Temperature on Electroretinograph Readings During Closed Vitrectomy in HumansArchives of Ophthalmology (1950), 1991
- Refinements in Microinstrumentation for Vitreous SurgeryAmerican Journal of Ophthalmology, 1990
- The Three-Port Microcannular System for Closed VitrectomyAmerican Journal of Ophthalmology, 1985