Abstract
Hemodynamic factors are thought to play important role in the initiation, growth, and rupture of cerebral aneurysms. However, hemodynamic features in the residual neck of incompletely occluded aneurysms and their influences on recanalization are rarely reported. This study characterized the hemodynamics of incompletely occluded aneurysms that had been confirmed to undergo recanalization during long-term follow-up using computational fluid dynamic analysis. A ruptured left basilar-SCA aneurysm was incompletely occluded and showed recanalization during 11 years follow-up period. We retrospectively characterized on three-dimensional MR angiography. After subtotal occlusion, the flow pattern, wall shear stress (WSS), and velocity at the remnant neck changed during long-term follow-up period. Specifically, high WSS region and high blood flow velocity were found near the neck. Interestingly, these area of the remnant neck coincided with the location of aneurysm recanalization. High WSS and blood flow velocity were consistently observed near the remnant neck of incompletely occluded aneurysm, prone to future recanalization. It will suggest that hemodynamic factors may play important roles in aneurismal recurrence after endovascular treatment.Keywords
This publication has 25 references indexed in Scilit:
- Clinical and angiographic long-term follow-up of completely coiled intracranial aneurysms using endovascular techniqueJournal of Neurosurgery, 2010
- Intra-Aneurysmal Hemodynamics during the Growth of an Unruptured Aneurysm: In Vitro Study Using Longitudinal CT Angiogram Database2007
- Repeat Endovascular Treatment in Post-Embolization Recurrent Intracranial AneurysmsNeurosurgery, 2006
- Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivityIEEE Transactions on Medical Imaging, 2005
- Evaluation of the Stability of Small Ruptured Aneurysms with a Small Neck after Embolization with Guglielmi Detachable Coils: Correlation between Coil Packing Ratio and Coil CompactionNeurosurgery, 2005
- Computational Replicas: Anatomic Reconstructions of Cerebral Vessels as Volume Numerical Grids at Three-Dimensional Angiography2004
- Image-Based Computational Simulation of Flow Dynamics in a Giant Intracranial Aneurysm2003
- Long-term Angiographic Follow-up of 169 Intracranial Berry Aneurysms Occluded with Detachable CoilsRadiology, 1999
- Platinum coil-mediated implantation of growth factor-secreting endovascular tissue grafts: an in vivo study.Radiology, 1998
- Does electrothrombosis occur immediately after embolization of an aneurysm with Guglielmi detachable coils?1997