Abstract
Background. The Nuss procedure was introduced in 1987 for the correction of pectus excavatum. In this procedure, a stainless steel bar is placed underneath the sternum. Objectives. To report cutaneous reactions associated with Nuss bar placement. Methods. Over a period of 30 months, 50 patients underwent the Nuss procedure. The study population was limited to those who developed clinically significant cutaneous reactions postoperatively. Patient information was obtained from electronic medical records. All patients had been patch tested preoperatively with stainless steel discs supplied by the bar manufacturer. When performed, expanded patch testing was carried out in accordance with the North American Contact Dermatitis Group guidelines. Results. Postoperatively, 3 patients developed areas of protuberant granulation tissue at one or more incision sites. One patient developed localized oedema, dermatitis, and lymphadenopathy. Two of these 4 patients underwent further patch testing. Of these 2, 1 with dermatitis had a positive reaction to nickel and the other, with granulation tissue, tested negative for metal allergy. Conclusions. Despite clinical evidence of cutaneous reactions or putative allergy, no patient required early removal of the bar(s). Cutaneous testing with stainless steel discs supplied by the bar manufacturer does not provide accurate screening for allergy to the implant used in the Nuss procedure.Keywords
This publication has 21 references indexed in Scilit:
- Surgical repair of pectus excavatumGeneral Thoracic and Cardiovascular Surgery, 2010
- Operative innovation to the “Nuss” procedure for pectus excavatum: operative and functional effectsJournal of Pediatric Surgery, 2009
- Early complications of the Nuss procedure for pectus excavatum: a prospective studyPediatric Surgery International, 2008
- Complications associated with the Nuss procedure: continued evolution of the learning curveThe American Journal of Surgery, 2008
- Sternal Plating to Correct an Unusual Complication of the Nuss Procedure: Erosion of a Pectus Bar Through the SternumThe Annals of Thoracic Surgery, 2008
- Erosion of the Nuss bar into the internal mammary artery 4 months after minimally invasive repair of pectus excavatumJournal of Pediatric Surgery, 2008
- When it is not an infection: metal allergy after the Nuss procedure for repair of pectus excavatumJournal of Pediatric Surgery, 2007
- Chest wall anomalies: pectus excavatum and pectus carinatumAdolescent Medicine Clinics, 2004
- The use of a lateral stabilizer increases the incidence of wound trouble following the Nuss procedureThe Annals of Thoracic Surgery, 2004
- Is the grass greener? Early results of the Nuss PprocedureJournal of Pediatric Surgery, 2000