The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections
Authors:
- M. BaxmannMBM. Baxmann
- S.Y. JauchSJS.Y. Jauch
- C. SchillingCSC. Schilling
- W. BlömerWBW. Blömer
- T.M. GruppTGT.M. Grupp
- M.M. MorlockMMM.M. Morlock
- 30 August 2012
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (5) , 676-683
Abstract
Modularity of femoral stems and neck components has become a more frequently used tool for an optimized restoration of the hip joint center and improvement of patient biomechanics. The additional taper interface increases the risk of mechanical failure due to fretting and crevice corrosion. Several failures of titanium alloy neck adapters have been documented in case-reports. An experimental fretting device was developed in this study to systematically investigate the effect of micromotion and contact pressure on fretting damage in contact situations similar to taper interfaces of modular hip prostheses under cyclic loading representative of in vivo load conditions. As a first application, the fretting behavior of Ti-6Al-4V titanium alloy components was investigated. Micromotions were varied between 10μm and 50μm, maximum contact pressures between 400 and 860N/mm(2). All modes of fretting damage were observed: Fretting wear was found for high micromotions in combination with low contact pressures. Fretting fatigue occurred with reduced movement or increased contact pressures. With small micromotions or high normal pressures, low fretting damage was observed. The developed device can be used to evaluate taper design (and especially contact geometry) as well as different materials prior to clinical use.Keywords
This publication has 40 references indexed in Scilit:
- Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant materialBMC Musculoskeletal Disorders, 2010
- Metal release and corrosion effects of modular neck total hip arthroplastyInternational Orthopaedics, 2009
- Fretting crevice corrosion of stainless steel stem–CoCr femoral head connections: Comparisons of materials, initial moisture, and offset lengthJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- The effect of surface treatments on the fretting behavior of Ti‐6Al‐4V alloyJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Frequency effect in fretting wear of Co‐28Cr‐6Mo versus Ti‐6Al‐4V implant alloysJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- Fretting wear in a modular neck hip prosthesisJournal of Biomedical Materials Research, 1997
- Design-related fretting wear in modular neck hip prosthesisJournal of Biomedical Materials Research, 1996
- Torsional resistance and wear of a modular sleeve-stem hip systemClinical Materials, 1993
- Fretting corrosion in saline and serumJournal of Biomedical Materials Research, 1981
- Ueber die Berührung fester elastischer Körper.Journal für die reine und angewandte Mathematik (Crelles Journal), 1882