Comparison of the Influence of Double-Limb Double-Plate Joint on the Stability Bearing Capacity of Triangular and Quadrilateral Transmission Tower Structures
Open Access
Abstract
The axial stiffness of the connection joints in a transmission tower will affect the stability bearing capacity of the tower. The axial stiffness of different forms of connection joints has different effects on the stability bearing capacities of triangular and quadrilateral lattice towers. This paper takes triangular and quadrilateral lattice towers as the comparative research objects and considers the influence of the stiffness of the single-limb, single-plate joint (SLSPJ) and double-limb, double-plate joint (DLDPJ) of the tower. Under vertical load, the vertical stability bearing capacities of triangular and quadrilateral transmission towers are studied from hte three aspects of theoretical analysis, numerical simulation and test result analysis. The influence rules of the SLSPJ and DLDPJ on the vertical stability bearing capacities of triangular and quadrilateral transmission towers are clarified. Through the energy method, considering the influence of the axial stiffness of connection joints, the calculation expressions of the vertical stability bearing capacities of triangular and quadrilateral lattice towers are derived. Through quantitative analysis, it is found that the axial stiffness of the connection joints has a more significant influence on the vertical stability bearing capacities of triangular lattice towers. The finite element models of the triangular and quadrilateral lattice towers including the SLSPJ and DLDPJ are further established. Through nonlinear finite element analysis, it is found that the DLDPJ can improve the vertical stability bearing capacity of the triangular lattice tower by 22.7% and the quadrilateral lattice tower by 14.9%. Through theoretical calculation, the expressions of the vertical stability bearing capacities of the triangular and quadrilateral lattice towers including the SLSPJ and DLDPJ are obtained. Combined with the test results of the SLSPJ and DLDPJ, it is found that the DLDPJ can improve the vertical stability bearing capacity of the triangular lattice tower by 23.4% and the quadrilateral lattice tower by 15.6%. The research results show that the DLDPJ can improve the vertical stability bearing capacities of triangular and quadrilateral lattice towers. The improvement effect of the vertical stability bearing capacity of the triangular lattice tower is 1.50∼1.52 times that of the quadrilateral lattice tower. The research results can provide a reference for the engineering popularization, application, and design of the DLDPJ in transmission towers.Keywords
This publication has 40 references indexed in Scilit:
- Study on ultimate bearing capacity of main member in transmission tubular tower legThin-Walled Structures, 2018
- Joint slip investigation based on finite element modelling verified by experimental results on wind turbine lattice towersFrontiers of Structural and Civil Engineering, 2017
- Experimental Study on the Mechanical Behavior and Failure Mechanism of a Latticed Steel Transmission TowerJournal of Structural Engineering, 2013
- Analysis and experimental testing of a built-up composite cross arm in a transmission line tower for mechanical performanceComposite Structures, 2013
- Studies on failure of transmission line towers in testingEngineering Structures, 2012
- Accurate modeling of joint effects in lattice transmission towersEngineering Structures, 2011
- Performance evaluation of a transmission tower by substructure testJournal of Constructional Steel Research, 2009
- Second-order analysis and design of angle trusses, Part II: Plastic analysis and designEngineering Structures, 2008
- Elastoplastic large deformation analysis of a lattice steel tower structure and comparison with full-scale testsJournal of Constructional Steel Research, 2007
- Effect of Bolt Slippage on Ultimate Behavior of Lattice StructuresJournal of Structural Engineering, 1994