Electrochemical biosensor for the simultaneous determination of rheumatoid factor and anti-cyclic citrullinated peptide antibodies in human serum
- 22 May 2020
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (13) , 4680-4687
Abstract
This paper reports a dual electrochemical biosensor involving carboxylated- or neutravidin-functionalized magnetic microbeads and dual screen-printed carbon electrodes for the simultaneous determination of rheumatoid factor (RF) and anti-cyclic citrullinated peptide (CCPA) autoantibodies used as biomarkers for the detection of rheumatoid arthritis autoimmune disease. Sandwich-type biosensors involving Fc fragments of IgG Fc(IgG) and biotinylated cyclic cytrullinated peptide (CCP-biotin) to form CCP-biotin-Neutr-MBs for the specific immobilization of RF and CCPA, respectively, as well as conjugation with HRP-IgM and HRP-IgG for RF and CCPA, respectively, were prepared. Amperometric detection was performed at −0.20 V vs. Ag pseudo-reference electrode using the H2O2/hydroquinone (HQ) system upon capturing the bioconjugates onto the corresponding working electrode (WE1 or WE2) of SPCdEs. The dual biosensor exhibits high sensitivity for RF and CCPA with LOD values of 0.8 and 2.5 IU mL−1, respectively. The simultaneous determination can be completed in about two hours using a simple protocol and a sample volume (25 μL) four times smaller than that required by the ELISA method. The dual electrochemical biosensor was used for the determination of both target biomarkers in human serum.Keywords
Funding Information
- Ministerio de Ciencia, Innovación y Universidades (RTI2018-096135-B-I00)
- Comunidad de Madrid (S2018/NMT-4349)
- Ministerio de Economía y Competitividad (CTQ2015-64402-C2-1-R)
This publication has 16 references indexed in Scilit:
- Estrogen receptor α determination in serum, cell lysates and breast cancer cells using an amperometric magnetoimmunosensing platformSensing and Bio-Sensing Research, 2016
- Label-free detection of rheumatoid factor using YbYxOy electrolyte–insulator–semiconductor devicesAnalytica Chimica Acta, 2015
- Biosensor analysis of anti-citrullinated protein/peptide antibody affinityAnalytical Biochemistry, 2014
- Autoantibodies in the autoimmune rheumatic diseasesMedicine, 2014
- Comparison of the Energetics of Avidin, Streptavidin, NeutrAvidin, and Anti-Biotin Antibody Binding to Biotinylated Lipid Bilayer Examined by Second-Harmonic GenerationAnalytical Chemistry, 2011
- Carbon nanotube composite peptide-based biosensors as putative diagnostic tools for rheumatoid arthritisBiosensors and Bioelectronics, 2011
- Arthritis development in patients with arthralgia is strongly associated with anti-citrullinated protein antibody status: a prospective cohort studyAnnals of the Rheumatic Diseases, 2010
- The use of citrullinated peptides and proteins for the diagnosis of rheumatoid arthritisArthritis Research & Therapy, 2010
- Anti–citrullinated peptide antibody assays and their role in the diagnosis of rheumatoid arthritisArthritis Care & Research, 2009
- Specific autoantibodies precede the symptoms of rheumatoid arthritis: A study of serial measurements in blood donorsArthritis & Rheumatism, 2004