Concomitant contact allergy to the resins, reactive diluents and hardener of a bisphenol A/F‐based epoxy resin in subway construction workers
- 7 March 2006
- journal article
- Published by Wiley in Contact Dermatitis
- Vol. 54 (3) , 131-139
Abstract
An outbreak of suspected contact dermatitis among subway construction workers was suspected to be due to a new bisphenol A/F‐based epoxy resin system (ERS). The construction workers used ERSs during the insertion of iron bars into concrete walls. The objective of the study was to determine the components (if any) of the ERS responsible for the contact allergy. Patch testing was performed on 20 of the 22 construction workers who had had contact with the ERS, and to the various subcomponents of component A on 5 of the 7 who reacted to this component. 9 patients (9/22, 40.9%) had clinical symptoms and signs of suspected contact dermatitis at presentation. 7 of these 9, but none of the 11 asymptomatic individuals, were positive to component A, while all were negative to component B. Of the 5 cases receiving further patch testing, all reacted to m‐xylylene diamine, 4 to 1,6‐hexanediol diglycidyl ether, 3 to epoxy resins of the bisphenol F‐type and trimethylolpropane triglycidyl ether 0.25% petrolatum, and only 1 to epoxy resins of the bisphenol A‐type. Contact allergy to ERSs may involve hardeners and diluents as well as resins, and patch testing for reaction to all components should be performed.Keywords
This publication has 25 references indexed in Scilit:
- Occupational allergic contact dermatitis to bisphenol F epoxy resinAustralasian Journal of Dermatology, 2005
- Prognosis of contact dermatitis in epoxy resin workersContact Dermatitis, 2005
- An attempt to improve diagnostics of contact allergy due to epoxy resin systems. First results of the multicentre study EPOX 2002Contact Dermatitis, 2004
- Chemical analysis of monomers in epoxy resins based on bisphenols F and AContact Dermatitis, 2004
- Occupational contact dermatitis due to the epoxy hardener m‐xylylenediamineContact Dermatitis, 2001
- Occupational contact dermatitis due to the epoxy hardener m-xylylenediamineContact Dermatitis, 2001
- Contact allergy to epoxy resin based on diglycidyl ether of bisphenol FContact Dermatitis, 2001
- 182 patients with occupational allergic epoxy contact dermatitis over 22 yearsContact Dermatitis, 2001
- Aziridine hardener - a new sensitizer in the dyeing of leatherContact Dermatitis, 2001
- Epicutaneous TestingAllergy, 1979