A rapid and sensitive p-benzoquinone-mediated bioassay for determination of heavy metal toxicity in water
- 28 March 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (11) , 3297-3302
Abstract
Determining and monitoring toxicity of chemicals in water are very important for human health and country security. Electrochemical measurement of respiratory chain activity is a rapid and reliable screening of the toxicity towards microorganisms. Here, we report a rapid and sensitive toxicity bioassay using p-benzoquinone as the artificial electron mediator and Escherichia coli as the test organism. Four heavy metal ions, Cu2+, Ag+, Hg2+ and Co2+, are tested as the model toxicants, and the corresponding 50% respiration inhibition concentrations (IC50) are determined to be 0.95, 8.14, 11.69 and 42.76 mg L−1, respectively. Based on the IC50 values, the descending order of toxicity is: Cu2+ > Ag+ > Hg2+ > Co2+. The presented bioassay not only provides a good foundation for further toxicity tests using E. coli, but also the potential for expanding the technique to utilize other bacteria with complementary toxicity responses, thereby allowing use of the bioassay in a wide range of applications.Keywords
This publication has 34 references indexed in Scilit:
- Toxicity assessment of various ionic liquid families towards Vibrio fischeri marine bacteriaEcotoxicology and Environmental Safety, 2012
- Development of a simple method for biotoxicity measurement using ultramicroelectrode array under non-deaerated conditionAnalytica Chimica Acta, 2011
- Cell-based biosensor for measurement of phenol and nitrophenols toxicityTalanta, 2011
- Direct toxicity assessment of toxic chemicals with electrochemical methodAnalytica Chimica Acta, 2009
- Toxicity assessment of heavy metals and organic compounds using CellSense biosensor with E.coliChinese Chemical Letters, 2008
- MICREDOX®—development of a ferricyanide-mediated rapid biochemical oxygen demand method using an immobilised Proteus vulgaris biocomponentBiosensors and Bioelectronics, 2004
- MICREDOX: application for rapid biotoxicity assessmentAnalytica Chimica Acta, 2004
- Combined physico-chemical and biological sensing in environmental monitoringBiosensors and Bioelectronics, 2003
- Analytical characterisation and application of a p-benzoquinone mediated amperometric graphite sensor with covalently linked glucoseoxidaseAnalytica Chimica Acta, 1995
- A comparison of three microbial assay procedures for measuring toxicity of chemical residuesArchives of Environmental Contamination and Toxicology, 1985