Passive Cavitation Detection With a Needle Hydrophone Array
- 14 October 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 233-240
Abstract
Therapeutic ultrasound and microbubble technologies seek to drive systemically administered microbubbles into oscillations that safely manipulate tissue or release drugs. Such procedures often detect the unique acoustic emissions from microbubbles with the intention of using this feedback to control the microbubble activity. However, most sensor systems reported introduce distortions to the acoustic signal. Acoustic shockwaves, a key emission from microbubbles, are largely absent in reported recording, possibly due to the sensors being too large or too narrowband, or having strong phase distortions. Here, we built a sensor array that countered such limitations with small, broadband sensors and a low phase distorting material. We built 8 needle hydrophones with polyvinylidene fluoride (PVDF, diameter: 2 mm) then fit them into a 3D-printed scaffold in a two-layered, staggered arrangement. Using this array, we monitored microbubbles exposed to therapeutically-relevant ultrasound pulses (center frequency: 0.5 MHz, peak-rarefactional pressure: 130-597 kPa, pulse length: 4 cycles). Our tests revealed that the hydrophones were broadband with the best having a sensitivity of -224.8± 3.2 dB re 1 V/μPa from 1 to 15 MHz. The array was able to capture shockwaves generated by microbubbles. The signal-to-noise (SNR) ratio of the array was approximately 2 times higher than individual hydrophones. Also, the array could localize microbubbles (-3dB lateral resolution: 2.37 mm) and determine the cavitation threshold (between 161 kPa and 254 kPa). Thus, the array accurately monitored and localized microbubble activities, and may be an important technological step towards better feedback control methods and safer and more effective treatments.Keywords
Funding Information
- Alzheimer’s Research U.K. (ARUK-IRG2017A-7)
This publication has 45 references indexed in Scilit:
- Blood-Brain Barrier: Real-time Feedback-controlled Focused Ultrasound Disruption by Using an Acoustic Emissions–based ControllerRadiology, 2012
- In vivotranscranial cavitation threshold detection during ultrasound-induced blood–brain barrier opening in micePhysics in Medicine & Biology, 2010
- Passive cavitation mapping for localization and tracking of bubble dynamicsThe Journal of the Acoustical Society of America, 2010
- Preparation of Hydrogel Substrates with Tunable Mechanical PropertiesCurrent Protocols in Cell Biology, 2010
- Passive cavitation imaging with ultrasound arraysThe Journal of the Acoustical Society of America, 2009
- Targeted disruption of the blood–brain barrier with focused ultrasound: association with cavitation activityPhysics in Medicine & Biology, 2006
- Localization of the complex spectrum: the S transformIEEE Transactions on Signal Processing, 1996
- A multiple-frequency hydrophone calibration techniqueThe Journal of the Acoustical Society of America, 1990
- PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipmentJournal of Physics E: Scientific Instruments, 1983
- Angular response of miniature ultrasonic hydrophonesMedical Physics, 1982