Deep Learning Segmentation of Triple-Negative Breast Cancer (TNBC) Patient Derived Tumor Xenograft (PDX) and Sensitivity of Radiomic Pipeline to Tumor Probability Boundary
Open Access
Abstract
Preclinical magnetic resonance imaging (MRI) is a critical component in a co-clinical research pipeline. Importantly, segmentation of tumors in MRI is a necessary step in tumor phenotyping and assessment of response to therapy. However, manual segmentation is time-intensive and suffers from inter- and intra- observer variability and lack of reproducibility. This study aimed to develop an automated pipeline for accurate localization and delineation of TNBC PDX tumors from preclinical T1w and T2w MR images using a deep learning (DL) algorithm and to assess the sensitivity of radiomic features to tumor boundaries. We tested five network architectures including U-Net, dense U-Net, Res-Net, recurrent residual UNet (R2UNet), and dense R2U-Net (D-R2UNet), which were compared against manual delineation by experts. To mitigate bias among multiple experts, the simultaneous truth and performance level estimation (STAPLE) algorithm was applied to create consensus maps. Performance metrics (F1-Score, recall, precision, and AUC) were used to assess the performance of the networks. Multi-contrast D-R2UNet performed best with F1-score = 0.948; however, all networks scored within 1–3% of each other. Radiomic features extracted from D-R2UNet were highly corelated to STAPLE-derived features with 67.13% of T1w and 53.15% of T2w exhibiting correlation ρ ≥ 0.9 (p ≤ 0.05). D-R2UNet-extracted features exhibited better reproducibility relative to STAPLE with 86.71% of T1w and 69.93% of T2w features found to be highly reproducible (CCC ≥ 0.9, p ≤ 0.05). Finally, 39.16% T1w and 13.9% T2w features were identified as insensitive to tumor boundary perturbations (Spearman correlation (−0.4 ≤ ρ ≤ 0.4). We developed a highly reproducible DL algorithm to circumvent manual segmentation of T1w and T2w MR images and identified sensitivity of radiomic features to tumor boundaries.Keywords
Funding Information
- National Cancer Institute (U24CA209837, U24CA253531, U54CA224083, U2CCA233303)
This publication has 53 references indexed in Scilit:
- Prognostic Value and Reproducibility of Pretreatment CT Texture Features in Stage III Non-Small Cell Lung CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2014
- Co-Clinical Trials Demonstrate Superiority of Crizotinib to Chemotherapy in ALK-Rearranged Non–Small Cell Lung Cancer and Predict Strategies to Overcome ResistanceClinical Cancer Research, 2014
- Endocrine-Therapy-Resistant ESR1 Variants Revealed by Genomic Characterization of Breast-Cancer-Derived XenograftsCell Reports, 2013
- Tumor grafts derived from women with breast cancer authentically reflect tumor pathology, growth, metastasis and disease outcomesNature Medicine, 2011
- Identification of human triple-negative breast cancer subtypes and preclinical models for selection of targeted therapiesJournal of Clinical Investigation, 2011
- Magnetic resonance imaging of the breast: Recommendations from the EUSOMA working groupEuropean Journal of Cancer, 2010
- Triple-Negative Breast Cancer: Correlation between MR Imaging and Pathologic FindingsRadiology, 2009
- Simultaneous Truth and Performance Level Estimation (STAPLE): An Algorithm for the Validation of Image SegmentationIEEE Transactions on Medical Imaging, 2004
- Accuracy and reproducibility of manual and semiautomated quantification of MS lesions by MRIJournal of Magnetic Resonance Imaging, 2003
- Least squares quantization in PCMIEEE Transactions on Information Theory, 1982