Protocol for the AutoRayValid-RBknee Study: a Retrospective, Multicenter, Fully-crossed, Multi-reader, Multi-case Study Investigating the Effect of a Knee Osteoarthritis Severity Classification Model on Reader Diagnostic Accuracy
Authors:
- Mathias Willadsen BrejnebølMBMathias Willadsen Brejnebøl
- Liv EgnellLELiv Egnell
- Michael LundemannMLMichael Lundemann
- Anders LenskjoldALAnders Lenskjold
- Janus Uhd NybingJNJanus Uhd Nybing
- Katharina ZiegelerKZKatharina Ziegeler
- Jacob VisserJVJacob Visser
- Kay Geert A. HermannKay Geert A. Hermann
- Edwin H.G. OeiEOEdwin H.G. Oei
- Mikael BoesenMBMikael Boesen
Preprint
Abstract
Background: Radiographic evaluation of knee osteoarthritis (KOA) commonly supports clinical findings. Ground truth is difficult to establish and concerns exist on the inter-and intrarater agreement of the findings. RBknee™ is a CE-marked and FDA-cleared AI tool for automatic assessment and reporting of radiographic KOA on standard projection radiographs. Objectives: To investigate how the use of an AI tool affects the accuracy among human readers across three European hospitals in grading the severity of osteoarthritis and associated individual radiographic features. In addition, the performance of the AI tool will also be compared to reference standards established by experts in a stand-alone validation. Methods: In this retrospective multicenter, fully-crossed, multi-reader, multi-case (MRMC) study, the AI support tool RBknee is introduced as a diagnostic intervention. Four Index Readers from each site (two orthopaedic surgeons and two radiologists) will read all studies twice in two runs separated by a washout period of at least four weeks. In both runs, the experiment will be arranged so that the AI-aid will be available for half of the images in the first session and for the second half of the images in the second session. The order of the images will be randomised in order to minimise temporal effects and biases. The primary endpoint is the difference in diagnostic test accuracy for radiographic KOA grading without and with the aid of the AI tool and will be measured as the ordinal weighted accuracy. Data: The data includes radiographic images from 225 studies (unique patients, retrospective data) with weight-bearing bilateral PA/AP and LAT projections of the symptomatic knee(s). Each site contributes to the cohort with 75 studies of which 70 will be consecutive and 5 will be selected to balance the prevalence of radiographic KOA severity. Reference standard: The reference standard will be established based on independent grading by three KOA Reference Experts and adjudicated by majority vote. Where impossible to resolve by majority voting, adjudication will be established by consensus. Index test, AI tool (stand-alone validation): The diagnostic accuracy of RBknee will be tested against the reference standard. Index test, Index Readers: The 12 readers will grade KL on the PA/AP projection and patellar osteophytes on the lateral projection. Administrative information: Title: The trial is titled “AutoRayValid-RBknee”. Protocol version: Revision History Funding: This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 954221 for the EIC SME Instrument project AutoRay. The work only reflects the authors’ view and the European Commission is not responsible for any use that may be made from the information it contains. Roles and responsibilities: Authors’ contributions: MWB, MB, EHGO, JV, and KGH initiated the study design and AL, JUN, KZ and HR helped with implementation. MWB, LE and MJL provided statistical expertise in clinical study design and MWB is conducting the primary statistical analysis. MWB, MJL and LE prepared the manuscript and all authors contributed to its refinement and approved the final manuscript. Sponsor Contact information: Trial Sponsor: Radiobotics ApS Contact name: Liv Egnell Address: Esplanaden 8C, 1263 Copenhagen K, Denmark Email: liv@radiobotics.comKeywords
This publication has 17 references indexed in Scilit:
- STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaborationBMJ Open, 2016
- Radiographic assessment of leg alignment and grading of knee osteoarthritis: A critical reviewWorld Journal of Rheumatology, 2015
- Defining the presence of radiographic knee osteoarthritis: a comparison between the Kellgren and Lawrence system and OARSI atlas criteriaKnee Surgery, Sports Traumatology, Arthroscopy, 2014
- World Medical Association Declaration of HelsinkiJAMA, 2013
- Validity and Reliability of Radiographic Knee Osteoarthritis Measures by Arthroplasty SurgeonsOrthopedics, 2013
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- EULAR evidence-based recommendations for the diagnosis of knee osteoarthritisAnnals of the Rheumatic Diseases, 2010
- Evidence for functional ATP-sensitive (KATP) potassium channels in human and equine articular chondrocytesOsteoarthritis and Cartilage, 2007
- Estimating and Comparing Diagnostic Tests’ Accuracy When the Gold Standard Is Not Binary1Academic Radiology, 2005
- Radiological Assessment of Osteo-ArthrosisAnnals of the Rheumatic Diseases, 1957