Abstract
The number of levels present in the torque-hysteresis controller influence the performance of the Direct Torque Controlled (DTC) induction motor drives. In this paper, the effects of the number of levels in the Torque-Hysteresis-Band-Controllers (THBCs) on the performance of the conventional DTC based three-level open-end winding induction motor drives are reported. A power-loss evaluation model was employed to investigate the influence of the number of levels present in THBC on the switching and conduction losses occurring in the dual-inverter system. The performance indices considered in this study are: (i) the fluxripple (ii) the torque-ripple and (iii) the total power-loss in the dual-inverter system. Furthermore, these performance indices are evaluated with a newly emerging control strategy, namely, the Predictive Torque Control (PTC) and are compared with those obtained with the DTC. The simulation results are validated by showing the experimental results.

This publication has 34 references indexed in Scilit: