Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment
Open Access
Abstract
Diabetes is a heterogeneous group of diseases that share a common trait of elevated blood glucose levels. Insulin lowers this level by promoting glucose utilization, thus avoiding short- and long-term organ damage due to the elevated blood glucose level. A patient with diabetes uses an insulin pump to dose insulin. The pump uses a controller to compute and dose the correct amount of insulin to keep blood glucose levels in a safe range. Insulin-pump controller development is an ongoing process aiming at fully closed-loop control. Controllers entering the market must be evaluated for safety. We propose an evaluation method that exploits an FDA-approved diabetic patient simulator. The method evaluates a Cartesian product of individual insulin-pump parameters with a fine degree of granularity. As this is a computationally intensive task, the simulator executes on a distributed cluster. We identify safe and risky combinations of insulin-pump parameter settings by applying the binomial model and decision tree to this product. As a result, we obtain a tool for insulin-pump settings and controller safety assessment. In this paper, we demonstrate the tool with the Low-Glucose Suspend and OpenAPS controllers. For average ± standard deviation, LGS and OpenAPS exhibited 1.7 ± 0.6% and 3.2 ± 1.8% of local extrema (i.e., good insulin-pump settings) out of all the entire Cartesian products, respectively. A continuous region around the best-discovered settings (i.e., the global extremum) of the insulin-pump settings spread across 4.0 ± 1.1% and 4.1 ± 1.3% of the Cartesian products, respectively.Keywords
Funding Information
- Západočeská Univerzita v Plzni (SGS-2022-015)
This publication has 29 references indexed in Scilit:
- The UVA/Padova Type 1 Diabetes Simulator Goes From Single Meal to Single DayJournal of Diabetes Science and Technology, 2018
- Evaluation of a Predictive Low-Glucose Management System In-ClinicDiabetes Technology & Therapeutics, 2017
- Using meta-differential evolution to enhance a calculation of a continuous blood glucose levelComputer Methods and Programs in Biomedicine, 2016
- The UVA/PADOVA Type 1 Diabetes SimulatorJournal of Diabetes Science and Technology, 2014
- Threshold-Based Insulin-Pump Interruption for Reduction of HypoglycemiaNew England Journal of Medicine, 2013
- Modelling using Polynomial RegressionProcedia Engineering, 2012
- A Review of the Security of Insulin Pump Infusion SystemsJournal of Diabetes Science and Technology, 2011
- In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 DiabetesJournal of Diabetes Science and Technology, 2009
- A Universally Unique IDentifier (UUID) URN Namespace2005
- Random decision forests2002