Valve-in-Valve in the Tricuspid Position for a Stenosed Bioprosthesis
Authors:
- Oved CohenOCOved Cohen
- Arthur KernerAKArthur Kerner
- Ariel RoguinARAriel Roguin
- Avishai ZiserAZAvishai Ziser
- Yoram AgmonYAYoram Agmon
- Gil BolotinGBGil Bolotin
- 3 April 2015
- journal article
- case report
- Published by IMR Press in The Heart Surgery Forum
- Vol. 16 (2) , 96-8
Abstract
The strategy of transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves is a documented approach. It allows one to avoid performing a high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has been documented only a few times in the literature. We report the case of a 65-year-old woman with a failing bioprosthetic tricuspid valve who had undergone 3 prior open heart operations. We attempted a transatrial transcatheter approach and successfully deployed a 29-mm Edwards Sapien balloon-expandable bioprosthesis into a severely stenotic tricuspid bioprosthesis. This case demonstrates the technical feasibility and safety of this approach.Keywords
This publication has 5 references indexed in Scilit:
- Transcatheter tricuspid valve replacement With the Edwards SAPIEN valveCatheterization and Cardiovascular Interventions, 2011
- Percutaneous Tricuspid Valve Replacement for a Stenosed BioprosthesisCirculation: Cardiovascular Interventions, 2010
- Transcatheter Valve-in-Valve Implantation for Failed Bioprosthetic Heart ValvesCirculation, 2010
- Heterotopic Valve Replacement as an Interventional Approach to Tricuspid RegurgitationJACC, 2010
- Outcomes and Safety of Percutaneous Aortic Valve ReplacementJACC, 2009