In vitro evaluation of a method for obtaining periapical radiographs for diagnosis of external apical root resorption
Open Access
- 1 June 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 30 (3) , 315-319
Abstract
This in vitro study was conducted to evaluate a method to obtain reproducible periapical radiographs, using individualized positioning devices, of upper central incisors submitted to simulated orthodontic movement. Linear measurements of tooth length were carried out on 29 extracted human central incisors. The teeth were radiographed in a tissue simulator, at different inclinations in the bucco-lingual direction (0 initial, 0 control, −10, −5, +5, and +10 degrees). The radiographs were digitized and quantitative analysis of tooth length was carried out using an electronic ruler. The linear measurements of tooth length were reproducible (r = 0.99) for repeated measurements as well as in the comparison of the initial and control images at 0 degree, where measurements did not differ significantly (analysis of variance, P = 0.827) in radiographs with different angulations. These results show that the method proposed for obtaining in vitro periapical radiographs results in reproducible images of tooth length, even when orthodontic movement is simulated by inclination of the tooth up to 20 degrees in the bucco-lingual direction.Keywords
This publication has 21 references indexed in Scilit:
- An overview of radiographic film holdersDentomaxillofacial Radiology, 2005
- Avaliação da padronização radiográfica para a subtração digital de imagensRevista da Faculdade de Odontologia de Porto Alegre, 2001
- Detection of simulated internal tooth resorption using conventional radiography and subtraction imagingDentomaxillofacial Radiology, 2001
- Quantitative analysis of apical root resorption by means of digital subtraction radiographyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2001
- Apical inflammatory root resorption: a correlative radiographic and histological assessmentInternational Endodontic Journal, 2000
- Radiographic assessment of simulated external root resorption cavities in maxillary incisorsDental Traumatology, 1998
- Validation of Quantitative Digital Subtraction Radiography Using the Electronically Guided Alignment Device/Impression TechniqueJournal of Periodontology, 1996
- Digital subtraction radiography for assessment of simulated root resorption cavities. Performance of conventional and reverse contrast modesDental Traumatology, 1992
- A simple paralleling instrument for superimposing radiographs of the molar regionsOral Surgery, Oral Medicine, Oral Pathology, 1988
- Influence of variations in projection geometry on the detectability of periodontal bone lesionsJournal of Clinical Periodontology, 1984