Temperature-Sensitive Frozen-Tissue Imaging for Cryoablation Monitoring Using STIR-UTE MRI
Authors:
- 1 May 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 55 (5) , 310-317
Abstract
Purpose: The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than −40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as an intraprocedural validation of the completion of tumor ablation, reducing the number of local recurrences after cryoablation procedures. Materials and Methods: The method relies on the short T 1 and T 2* relaxation times of frozen soft tissue. Pointwise Encoding Time with Radial Acquisition, a 3-dimensional UTE sequence with TE = 70 microseconds, was optimized with STIR to null tissues with a T 1 of approximately 271 milliseconds, the threshold T 1. Because the T 1 relaxation time of frozen tissue in the temperature range of −40°C < temperature < −8°C is shorter than the threshold T 1 at the 3-tesla magnetic field, tissues in this range should appear hyperintense. The sequence was evaluated in ex vivo frozen tissue, where image intensity and actual tissue temperatures, measured by thermocouples, were correlated. Thereafter, the sequence was evaluated clinically in 12 MR-guided prostate cancer cryoablations, where MR-compatible cryoprobes were used to destroy cancerous tissue and preserve surrounding normal tissue. Results: The ex vivo experiment using a bovine muscle demonstrated that STIR-UTE images showed regions approximately between −40°C and −8°C as hyperintense, with tissues at lower and higher temperatures appearing dark, making it possible to identify the region likely to be above the lethal temperature inside the frozen tissue. In the clinical cases, the STIR-UTE images showed a dark volume centered on the cryoprobe shaft, V inner, where the temperature is likely below −40°C, surrounded by a doughnut-shaped hyperintense volume, where the temperature is likely between −40°C and −8°C. The hyperintense region was itself surrounded by a dark volume, where the temperature is likely above −8°C, permitting calculation of V outer. The STIR-UTE frozen-tissue volumes, V inner and V outer, appeared significantly smaller than signal voids on turbo spin echo images (P < 1.0 × 10−6), which are currently used to quantify the frozen-tissue volume (“the iceball”). The ratios of the V inner and V outer volumes to the iceball were 0.92 ± 0.08 and 0.29 ± 0.07, respectively. In a single postablation follow-up case, a strong correlation was seen between V inner and the necrotic volume. Conclusions: Short tau inversion-recovery ultrashort echo-time MR imaging successfully delineated the area approximately between −40°C and −8°C isotherms in the frozen tissue, demonstrating its potential to monitor the lethal ablation volume during MR-guided cryoablation.Keywords
This publication has 34 references indexed in Scilit:
- Real-Time Magnetic Resonance Imaging–Guided Cryoablation of Small Renal Tumors at 1.5 TInvestigative Radiology, 2013
- Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)Magnetic Resonance in Medicine, 2011
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- Consistency of signal intensity and T2* in frozen ex vivo heart muscle, kidney, and liver tissueJournal of Magnetic Resonance Imaging, 2010
- Acquisition‐weighted stack of spirals for fast high‐resolution three‐dimensional ultra‐short echo time MR imagingMagnetic Resonance in Medicine, 2008
- Cryosurgical technique: Assessment of the fundamental variables using human prostate cancer model systemsCryobiology, 2007
- In Vivo MR Thermometry of Frozen Tissue Using R2* and Signal Intensity1Academic Radiology, 2005
- The state of water in biological systems as studied by proton and deuterium relaxationBiochimica et Biophysica Acta (BBA) - General Subjects, 1975
- Non-freezable water and spin-lattice relaxation time in muscle containing a growing tumorBiochimica et Biophysica Acta (BBA) - General Subjects, 1974
- The state of water in muscle as studied by pulsed NMRBiochimica et Biophysica Acta (BBA) - General Subjects, 1974