Estimating effective dose using non-lead protective aprons and a single dosimeter method
Open Access
- 14 January 2026
- journal article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (1)
Abstract
Objective: Fluoroscopic interventional procedures subject healthcare personnel to significant ionizing radiation exposure, necessitating the use of protective aprons. Protective aprons are made of varying materials and may be subjected to inadequate testing standards, leading to potential inaccuracies estimating effective dose when using single dosimeter methods. This study aims to develop an appropriate method to estimate effective dose for non-lead aprons using a single dosimeter worn outside the apron, thereby enhancing radiation protection and reducing musculoskeletal injuries to workers. Approach: A retrospective, secondary analysis of existing literature was conducted to derive a dataset suitable for algorithm development. Transmission of radiation through the protective apron at various thicknesses was modeled using exponential regression. The resulting equation incorporates the nominal lead equivalent thickness to estimate effective dose. Validation was performed by comparing algorithms using two-dosimeters, which do not rely on apron shielding assumptions. Main Results: The dataset comprised 205 dosimeter readings from 42 physicians across 8,243 procedures (Fetterly et al.). The derived equation, E=H_0 (0.13+1.02e^((-11.33x) ) ), demonstrated minimal underestimation, and a potential overestimation of up to 1.3-fold relative to the true effective dose, improving upon previous methods by 15%. Inclusion of a non-lead thyroid collar reduced effective dose by 17-30%. Use of accessory upper body shielding is required when using this method. Significance: This novel method provides a method to estimate the effective dose using non-lead aprons at varying nominal lead equivalent thicknesses, surpassing previous single dosimeter approaches. The findings support improved optimization of radiation protection during fluoroscopic interventional procedures, may inform radiation safety regulations, and support ergonomic improvements.Keywords
This publication has 35 references indexed in Scilit:
- Occupational Health Hazards in the Cardiac Catheterization Laboratory: Results of the 2023 SCAI SurveyJournal of the Society for Cardiovascular Angiography & Interventions, 2025
- Radiation Exposure and Protection for (Assumed) Pregnant Interventional Cardiologists and ElectrophysiologistsJournal of the Society for Cardiovascular Angiography & Interventions, 2024
- The association between musculoskeletal disorders and lead apron use in healthcare workers: A systematic review and meta-analysisSafety Science, 2024
- Intraprocedural ergonomics of vascular surgeonsJournal of Vascular Surgery, 2021
- Technical Note: Assessment of scatter originating from the x‐ray tube collimator assembly of modern angiography systemsMedical Physics, 2019
- Optimization of the double dosimetry algorithm for interventional cardiologistsRadiation Physics and Chemistry, 2014
- Conversion Coefficients for Radiological Protection Quantities for External Radiation ExposuresAnnals of the ICRP, 2010
- Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional RadiologyCardioVascular and Interventional Radiology, 2009
- Preface, Executive Summary and GlossaryAnnals of the ICRP, 2007
- Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shieldingThe American Journal of Cardiology, 2002