Abstract
This study investigates the feasibility of utilizing the line loss power factor to assess the reactive, unbalanced, and harmonic line losses in low-voltage distribution networks and explores the method of calculating decoupled line loss values based on this factor. To achieve this objective, we establish preliminary definitions of single-phase and three-phase reactive, unbalanced, and harmonic line loss power factors, drawing upon the principles of electrical theory outlined in IEEE Standard 1459. These power factors serve as crucial indicators for evaluating the severity of line losses caused by reactive power, unbalance, and harmonic problems. Subsequently, the values of line loss attributed to reactive, unbalanced, and harmonic components are decoupled and quantified using the line loss power factor as a fundamental parameter. The effectiveness and accuracy of the proposed method were verified in Matlab simulation and physical experiments.Keywords
This publication has 17 references indexed in Scilit:
- Theoretical line loss calculation method for low-voltage distribution network via matrix completion and ReliefF-CNNEnergy Reports, 2023
- A novel optimization strategy for line loss reduction in distribution networks with large penetration of distributed generationInternational Journal of Electrical Power & Energy Systems, 2023
- Tariff rationalization for reactive power and harmonics regulation in low voltage distribution networksElectrical Engineering, 2022
- Modeling and open source implementation of balanced and unbalanced harmonic analysis in radial distribution networksElectric Power Systems Research, 2022
- A newly effective method to maximize power loss reduction in distribution networks with highly penetrated distributed generationsAin Shams Engineering Journal, 2021
- Measurement of Simplified Single- and Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010IEEE Transactions on Instrumentation and Measurement, 2021
- Determining penetration limit of central PVDG topology considering the stochastic behaviour of PV generation and loads to reduce power losses and improve voltage profilesIET Renewable Power Generation, 2020
- An overview of unbalance compensation techniques using power electronic converters for active distribution systems with renewable generationRenewable and Sustainable Energy Reviews, 2020
- A New Model for Reconfiguration and Distributed Generation Allocation in Distribution Network Considering Power Quality Indices and Network LossesIEEE Systems Journal, 2020
- Distribution Network Reconfiguration for Loss Reduction and Voltage Stability With Random Fuzzy Uncertainties of Renewable Energy Generation and LoadIEEE Transactions on Industrial Informatics, 2018