Field comparison of passive air samplers with reference monitors for ambient volatile organic compounds and nitrogen dioxide under week-long integrals
Authors:
- 8 October 2008
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 11 (1) , 220-227
Abstract
This study evaluates performance of nitrogen dioxide (NO2) and volatile organic compound (VOC) passive samplers with corresponding reference monitors at two sites in the Detroit, Michigan area during the summer of 2005. Ogawa passive NO2 samplers and custom-made, re-useable Perkin-Elmer (PE) tubes with Carbopack X sorbent for VOCs were deployed under week-long sampling periods for six weeks. Precise results (5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was also good for duplicate PE tubes for benzene, toluene, ethylbenzene, and xylene isomers (BTEX species, all ≤ 6% RSD). As seen in previous studies, comparison of Ogawa NO2 samplers with reference chemiluminescence measurements suggested good agreement. Generally good agreement was also found between the PE tubes and reference methods for BTEX species.Keywords
This publication has 23 references indexed in Scilit:
- Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: A reviewJournal of Exposure Science & Environmental Epidemiology, 2008
- Evaluation of ogawa passive sampling devices as an alternative measurement method for the nitrogen dioxide annual standard in El Paso, TexasEnvironmental Monitoring and Assessment, 2006
- Nitrogen dioxide prediction in Southern California using land use regression modeling: potential for environmental health analysesJournal of Exposure Science & Environmental Epidemiology, 2005
- Measurements of environmental 1,3-butadiene with pumped and diffusive samplers using the sorbent Carbopack XAtmospheric Environment, 2005
- 24 h diffusive sampling of toxic VOCs in air onto Carbopack X solid adsorbent followed by thermal desorption/GC/MS analysis—laboratory studiesJournal of Environmental Monitoring, 2005
- Ambient nitrogen dioxide and distance from a major highwayScience of The Total Environment, 2003
- Comparison of measurement methods for benzene and tolueneAtmospheric Environment, 2003
- Evaluation of a Passive Sampler for Volatile Organic Compounds at ppb Concentrations, Varying Temperatures, and Humidities with 24-h Exposures. 2. Sampler PerformanceEnvironmental Science & Technology, 1999
- A badge-type personal sampler for measurement of personal exposure to NO2 and NO in ambient airEnvironment International, 1982
- Development and application of a diffusional sampler for NO2Environment International, 1981