Three-dimensional sonographic evaluation of gallbladder contractility: Comparison with cholescintigraphy
- 1 March 2006
- journal article
- research article
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 34 (3) , 123-127
Abstract
Purpose: To compare three‐dimensional sonography (3D US) with quantitative cholescintigraphy for assessing gallbladder contractility. Methods: Gallbladder radioactivity was assessed in 35 patients with suspected gallbladder disease using a gamma camera 5, 30, 60, and 90 minutes after technetium 99m (Tc‐99m) DISIDA injection and 30 and 60 minutes after ingestion of a high‐fat meal. Immediate gallbladder images were obtained via 3D US. Gallbladder radioactivity at 120 minutes after injection of Tc‐99m DISIDA was defined as 100%, and gallbladder contractility was calculated. Gallbladder volume on 3D US was calculated using a dedicated software. Pearson correlation analysis and simple linear regression analysis were used. Results: The mean gallbladder volume on 3D US was 25.3 ml after fasting and 6.6 ml after a high‐fat meal. The mean gallbladder contractility index was 77.7% on cholescintigraphy (range, 18–99) and 73.4 on 3D US (range, 16.7–97.3). A linear correlation between cholescintigraphy and 3D US contractility indices was observed. The r value on Pearson analysis was 0.92 and R2 of the coefficient of determination was 0.85. The difference in measured contractility between the 2 methods ranged from +21.5% to −15.0% (mean ± SD, 4.4 ± 8.7%). Conclusions: 3D US is a reliable and easy method for clinical measurement of the volume of the gallbladder and its contractility. © 2006 Wiley Periodicals, Inc. J Clin Ultrasound 34:123–127, 2006Keywords
This publication has 12 references indexed in Scilit:
- Reproducibility of Fetal Lung Volume Measurements With 3‐Dimensional UltrasonographyJournal of Ultrasound in Medicine, 2004
- Accuracy of bladder volume determinations by ultrasonography: are they accurate over entire bladder volume range?Urology, 2003
- Semiautomatic three-dimensional segmentation of the prostate using two-dimensional ultrasound imagesMedical Physics, 2003
- An Evaluation of Three-Dimensional Ultrasonography for The Measurement of Gallbladder VolumeAmerican Journal of Gastroenterology, 1999
- Correlation of Gallbladder Ejection Fraction With Pathologic Grade for Chronic InflammationSouthern Medical Journal, 1998
- Evaluation of gallbladder volume and emptying with a novel three-dimensional ultrasound system: Comparison with the sum-of-cylinders and the ellipsoid methodsJournal of Clinical Ultrasound, 1996
- Distance and volume measurement using three-dimensional ultrasonography.Journal of Ultrasound in Medicine, 1995
- Gallbladder Volume and Contraction Measured by Sum-of-Cylinders Method Compared with Ellipsoid and Area-Length MethodsActa Radiologica, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- An analysis of the reaction of the human gall bladder to foodThe Anatomical Record, 1928