Chemiluminescence microflow injection analysis system on a chip for the determination of uric acid without enzyme
Authors:
- 1 July 2005
- journal article
- research article
- Published by Wiley in Luminescence
- Vol. 20 (4-5) , 271-275
Abstract
A new microflow injection analysis (µFIA) system on a chip coupled with chemiluminescence (CL) for the non‐enzymatic determination of uric acid is described. The µFIA system produced by using two transparent poly(methylmethacrylate) (PMMA) chips measured 50 × 40 × 5 mm, the microchannels, etched by CO2 laser, were 200 µm wide and 100 µm deep, and the volume of the reaction area (RA) was about 1.2 µL. The injection pump, with accurate time control, monitored all reagents, including the sample. The uric acid was sensed by the chemiluminescence reaction between luminol and ferricyanide. The linear range of the uric acid concentration was 0.8–30 mg/L and the detection limit was 0.5 mg/L (S/N = 3). The relative standard deviation was 4.42% for 5 mg/L uric acid (n = 8). The proposed method has been successfully applied to the non‐separation determination of uric acid in human serum and urine. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 19 references indexed in Scilit:
- Flow injection analysis of uric acid with a uricase- and horseradish peroxidase-coupled Sepharose column based luminol chemiluminescence systemAnalytica Chimica Acta, 2003
- Microdialysis sampling and monitoring of uric acid in vivo by a chemiluminescence reaction and an enzyme on immobilized chitosan support membraneAnalytica Chimica Acta, 2003
- Simultaneous detection of uric acid and glucose on a dual-enzyme chip using scanning electrochemical microscopy/scanning chemiluminescence microscopyAnalytica Chimica Acta, 2002
- The development of an on-chip micro-flow injection analysis of nitrate with a cadmium reductorAnalytica Chimica Acta, 2001
- On-line monitoring of chromium(iii) using a fast micromachined mixer/reactor and chemiluminescence detectionThe Analyst, 2000
- Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determinationAnalytica Chimica Acta, 2000
- Sequential injection sample introduction microfluidic-chip based capillary electrophoresis systemAnalytica Chimica Acta, 1999
- Chemiluminescence flow injection analysis of reducing agents based on the luminol reactionAnalytica Chimica Acta, 1997
- Fused Quartz Substrates for Microchip ElectrophoresisAnalytical Chemistry, 1995
- Rapid separation of fluorescein derivatives using a micromachined capillary eletrophoresis systemAnalytica Chimica Acta, 1993