Relevance of Electrical Remodeling in Human Atrial Fibrillation
Authors:
- Jeff S. HealeyJHJeff S. Healey
- Carsten W. IsraelCICarsten W. Israel
- Stuart J. ConnollySCStuart J. Connolly
- Stefan H. HohnloserSHStefan H. Hohnloser
- Girish M. NairGNGirish M. Nair
- Syamkumar DivakaramenonSDSyamkumar Divakaramenon
- Alessandro CapucciACAlessandro Capucci
- Isabelle C. Van GelderIGIsabelle C. Van Gelder
- Chu-Pak LauCLChu-Pak Lau
- Michael R. GoldMGMichael R. Gold
- Mark CarlsonMCMark Carlson
- Ellison ThemelesETEllison Themeles
- 1 August 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 5 (4) , 626-631
Abstract
Background—: In animal models of atrial fibrillation (AF), changes in atrial electrophysiological properties are associated with the development of AF. Their relevance to human AF is unclear. Methods and Results—: The Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial enrolled 2580 patients receiving a dual-chamber pacemaker, who were older than the age of 65 and had a history of hypertension, but no history of AF. Serial noninvasive electrophysiological testing was performed over 2 years in a subgroup of 485 patients. There were no differences in the clinical characteristics between patients with and those without device-detected atrial tachyarrhythmias during the first year. Patients with atrial tachyarrhythmias had longer paced (153±29 versus 145±28 ms; P =0.046) and sensed (128±46 versus 118±25 ms; P =0.06) P-wave durations and were more likely to have AF induced during electrophysiological testing (23.5% versus 13.6%; P =0.03). They had similar corrected sinus node recovery times at 90 bpm (388±554 versus 376 ± 466 ms; P =0.86), atrial effective refractory periods at 90 bpm (250±32 versus 248±36 ms; P =0.70), and rate-adaptive shortening of the atrial effective refractory periods (14±13 versus 12±14 ms; P =0.11). There were no significant differences in the change in electrophysiological properties over 2 years between patients with and those without atrial tachyarrhythmias. Conclusions—: Prolonged P-wave duration, but not differences in atrial effective refractory periods, was associated with the development of atrial tachyarrhythmias in pacemaker patients.Keywords
This publication has 27 references indexed in Scilit:
- Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node DiseaseNew England Journal of Medicine, 2007
- ASymptomatic atrial fibrillation and Stroke Evaluation in pacemaker patients and the atrial fibrillation Reduction atrial pacing Trial (ASSERT)American Heart Journal, 2006
- Cardiovascular Outcomes With Atrial-Based Pacing Compared With Ventricular PacingCirculation, 2006
- Age-associated changes in electrophysiologic remodeling: a potential contributor to initiation of atrial fibrillationCardiovascular Research, 2005
- Sinus and Paced P Wave Duration and Dispersion as Predictors of Atrial Fibrillation After Pacemaker Implantation in Patients with Isolated Sick Sinus SyndromePacing and Clinical Electrophysiology, 2004
- Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring deviceJACC, 2004
- Electrical Remodeling of the Atria in Congestive Heart FailureCirculation, 2003
- Effect of ethnicity and hypertension on atrial conduction: Evaluation with high‐resolution p‐wave signal averagingClinical Cardiology, 2001
- Prevalence, incidence, prognosis, and predisposing conditions for atrial fibrillation: population-based estimates 11Reprints are not available.The American Journal of Cardiology, 1998
- Electrical Remodeling of the Human Atrium: Similar Effects in Patients With Chronic Atrial Fibrillation and Atrial FlutterJACC, 1997