A radiomagnetotelluric survey on an oil‐contaminated area near the Brazi Refinery, Romania
Authors:
- 14 April 2005
- journal article
- Published by Wiley in Geophysical Prospecting
- Vol. 53 (3) , 311-323
Abstract
Scalar radiomagnetotelluric measurements were carried out on a contaminated test area close to the Brazi Refinery in Romania in order to detect and to monitor a 1 m thick oil layer expected at 5 m depth. Radio transmitters broadcasting in a frequency range from 10 kHz to 300 kHz were selected to observe the apparent resistivity and the phase data associated with the E‐ and B‐polarizations. They were located parallel and perpendicular to the assumed strike direction of the contamination plume. The data were interpreted by a 2D inversion technique from which the conductivity structure of the area was derived. The 2D inversion models of all profiles on the contaminated area show a poor‐conductivity zone above the groundwater table which could be associated with the oil contamination.A first attempt was also made to monitor the contaminated layer: the radiomagnetotelluric measurements were repeated on the same profiles a year later, but this time in a dry period, not in a rainy one. The 2D inversion results of the measurements in the dry period indicate that the high‐resistivity layer moved closer to the surface. Additional reference measurements were then carried out on a non‐contaminated area situated at a distance from the refinery, in the opposite direction to the flow of the groundwater. These reference measurements were used for the derivation of the unperturbed geology and they were also compared with the measurements of the contaminated test area. There is a significant difference in the frequency dependences of the apparent resistivities of the reference and contaminated areas, which could indicate a contamination at shallow depth. The 2D inversion results show the increase of resistivity at a depth of about 5 m beneath the contaminated area where the oil contamination is expected according to the information from the boreholes.Keywords
This publication has 14 references indexed in Scilit:
- A model for the resistivity structure of LNAPL plumes and their environs in sandy sedimentsJournal of Applied Geophysics, 2000
- Detection of hydrocarbon contaminated soil with radiomagnetotellurics1998
- MAPPING OIL‐CONTAMINATED SAND AND TILL WITH THE SPECTRAL INDUCED POLARIZATION (SIP) METHODGeophysical Prospecting, 1997
- Application of complex resistivity tomography to field data from a kerosene-contaminated site1997
- 1D joint inversion of radiomagnetotellluric (RMT) and transient-electromagnetic (TEM) data: an application for groundwater prospection in Grundfør, Denmark1997
- A joint application of radiomagnetotellurics and transient electromagnetics to the investigation of a waste deposit in Cologne (Germany)Journal of Applied Geophysics, 1996
- Modelling the Electrical Properties of Porous Rocks and Soils Containing Immiscible ContaminantsJournal of Environmental and Engineering Geophysics, 1996
- Hydrogeological investigation of porous environments by radio magnetotelluric-resistivity (RMT-R 12–240 kHz)Journal of Applied Geophysics, 1994
- Low-frequency electrical propertiesGeophysics, 1985
- Basic theory of the magneto-telluric method of geophysical prospectingGeophysics, 1953