Surgical glue-induced left main trunk stenosis removed by directional coronary atherectomy
Open Access
- 21 September 2021
- journal article
- editorial
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 34 (1) , 162-164
Abstract
A 55-year-old man underwent aortic repair for acute aortic dissection. The pseudolumen of the Valsalva sinus was reapproximated with BioGlue by placing a sponge inside of it to prevent the BioGlue from entering. Postoperative contrast-enhanced computed tomography showed stenosis of the left main trunk. Directional coronary atherectomy was performed; complete release of the stenosis was achieved. Various fragments retrieved from the left main trunk were pathologically consistent with BioGlue. When we reapproximated the dissected aortic wall, inserting a sponge into the aorta did not prevent the surgical glue from entering. Directional coronary atherectomy was a good therapeutic option to treat glue-induced coronary artery stenosis.Keywords
This publication has 4 references indexed in Scilit:
- [Coronary Embolism Probably Caused by Surgical Glue after Operation for Acute Aortic Dissection;Report of a Case].2016
- Acute Limb Ischaemia Due to Embolisation of Biological Glue 45 Days After SurgeryEuropean Journal of Vascular and Endovascular Surgery, 2011
- Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissectionInteractive CardioVascular and Thoracic Surgery, 2005
- Acute coronary syndrome following repair of aortic dissectionEuropean Journal of Cardio-Thoracic Surgery, 2004