Status of the Brookhaven National Laboratory high current electron beam ion source test stand

Authors:

Abstract
As part of a new, compact heavy ion injector for the AGS/RHIC complex at Brookhaven National Laboratory we are developing an electron beam ion source (EBIS) that would satisfy present and future requirements. Such a source should be capable of producing intensities of, e.g., Au35+ ions of about 3×109 particles/pulse or U45+ of about 2×109 particles/pulse. To achieve this, the required e-beam intensity is 10 A, at a pulse length of 100 ms. An EBIS test stand has been constructed, designed for the full electron beam power and having close to 1/2 of the trap length of an EBIS for RHIC. Initial electron beam tests have resulted in a 50 μs, 13 A electron beam. Ion production and extraction has been shown with a 3.1 A, 50 ms electron beam, achieving an ion yield of 19 nC/pulse (neutralization degree of 61%); fast extraction trials have yielded extracted ion pulses of 1 mA peak current and 18 μs at FWHM. Details of the test stand construction, results of the electron beam studies, and properties of the extracted ion pulse are presented.

This publication has 5 references indexed in Scilit: