Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor
- 31 August 2018
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (27) , 7249-7260
Abstract
There is a need for blood glucose monitoring techniques that eliminate the painful and invasive nature of current methods, while maintaining the reliability and accuracy of established medical technology. This research aims to ultimately address these shortcomings in critically ill pediatric patients. Presented in this work is an alternative, minimally invasive technique that uses microneedles (MN) for the collection of transdermal glucose (TG). Due to their comparable skin properties, diffusion studies were performed on full thickness Yucatan miniature pig skin mounted to an in-line diffusion flow cell and on different skin sites of human subjects. Collected TG samples were measured with a L255C mutant of the E. coli glucose-binding protein (GBP) with an attached fluorescent probe. The binding constant (Kd = 0.67 μM) revealed the micromolar sensitivity and high selectivity of the his-tagged GBP biosensor for glucose, making it suitable for TG measurements. In both the animal and human models, skin permeability and TG diffusion across the skin increased with MN application. For intact and MN-treated human skin, a significant positive linear correlation (r > 0.95, p < 0.01) existed between TG and BG. The micromolar sensitivity of GBP minimized the volume required for interstitial fluid glucose analysis allowing MN application time (30 s) to be shortened compared to other studies. This time reduction can help in eliminating skin irritation issues and improving practical use of the technique by caregivers in the hospital. In addition, the his-tagged optical biosensor used in this work can be immobilized and used with a portable sensing fluorometer device at the point of care (POC) making this minimally invasive technology more ideal for use in the pediatric intensive care unit.Keywords
Funding Information
- UMB-UMBC Research and Innovation Partnership Grant Program
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R41HD088223)
This publication has 43 references indexed in Scilit:
- Spectral characteristics of the mutant form GGBP/H152C of D-glucose/D-galactose-binding protein labeled with fluorescent dye BADAN: influence of external factorsPeerJ, 2014
- Continuous Glucose Monitoring in Newborn Babies at Risk of HypoglycemiaThe Journal of Pediatrics, 2010
- Continuous Glucose Monitors and the Burden of Tight Glycemic Control in Critical Care: Can They Cure the Time Cost?Journal of Diabetes Science and Technology, 2010
- Diabetic ketoacidosis in children and adolescents with diabetesPediatric Diabetes, 2009
- On the Possibility of Real‐Time Monitoring of Glucose in Cell Culture by Microdialysis Using a Fluorescent Glucose Binding Protein SensorBiotechnology Progress, 2008
- Prospective detection of hyperglycemia in critically ill children using continuous glucose monitoring*Pediatric Critical Care Medicine, 2008
- Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac SurgeryPediatrics, 2006
- Association of Hypoglycemia, Hyperglycemia, and Glucose Variability With Morbidity and Death in the Pediatric Intensive Care UnitPediatrics, 2006
- The continuous glucose monitoring sensor in neonatal intensive careArchives of Disease in Childhood - Fetal and Neonatal Edition, 2005
- Dual-Labeled Glucose Binding Protein for Ratiometric Measurements of GlucoseAnalytical Chemistry, 2004