Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT
Open Access
- 6 February 2017
- journal article
- cardiac
- Published by Springer Nature in European Radiology
- Vol. 27 (9) , 3904-3912
Abstract
Objective To determine the accuracy of iodine quantification with dual energy computed tomography (DECT) in two high-end CT systems with different spectral imaging techniques. Methods Five tubes with different iodine concentrations (0, 5, 10, 15, 20 mg/ml) were analysed in an anthropomorphic thoracic phantom. Adding two phantom rings simulated increased patient size. For third-generation dual source CT (DSCT), tube voltage combinations of 150Sn and 70, 80, 90, 100 kVp were analysed. For dual layer CT (DLCT), 120 and 140 kVp were used. Scans were repeated three times. Median normalized values and interquartile ranges (IQRs) were calculated for all kVp settings and phantom sizes. Results Correlation between measured and known iodine concentrations was excellent for both systems (R = 0.999–1.000, p < 0.0001). For DSCT, median measurement errors ranged from −0.5% (IQR −2.0, 2.0%) at 150Sn/70 kVp and −2.3% (IQR −4.0, −0.1%) at 150Sn/80 kVp to −4.0% (IQR −6.0, −2.8%) at 150Sn/90 kVp. For DLCT, median measurement errors ranged from −3.3% (IQR −4.9, −1.5%) at 140 kVp to −4.6% (IQR −6.0, −3.6%) at 120 kVp. Larger phantom sizes increased variability of iodine measurements (p < 0.05). Conclusion Iodine concentration can be accurately quantified with state-of-the-art DECT systems from two vendors. The lowest absolute errors were found for DSCT using the 150Sn/70 kVp or 150Sn/80 kVp combinations, which was slightly more accurate than 140 kVp in DLCT. Key Points • High-end CT scanners allow accurate iodine quantification using different DECT techniques. • Lowest measurement error was found in scans with largest photon energy separation. • Dual-source CT quantified iodine slightly more accurately than dual layer CT.Keywords
Funding Information
- Rijksuniversiteit Groningen
This publication has 19 references indexed in Scilit:
- Initial Results of a Single-Source Dual-Energy Computed Tomography Technique Using a Split-FilterInvestigative Radiology, 2016
- Dual-energy CT-based iodine quantification for differentiating pulmonary artery sarcoma from pulmonary thromboembolism: a pilot studyEuropean Radiology, 2015
- New Applications of Cardiac Computed TomographyJACC: Cardiovascular Imaging, 2015
- Diagnostic Performance of Dual-Energy CT Stress Myocardial Perfusion Imaging: Direct Comparison With Cardiovascular MRIAmerican Journal of Roentgenology, 2014
- Advanced modelled iterative reconstruction for abdominal CT: Qualitative and quantitative evaluationClinical Radiology, 2014
- Dual-energy CT and its potential use for quantitative myocardial CT perfusionJournal of Cardiovascular Computed Tomography, 2012
- Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal MassesAmerican Journal of Roentgenology, 2011
- Prognostic Value of Cardiac Computed Tomography AngiographyJACC, 2011
- A review of the cost of cardiovascular diseaseCanadian Journal of Cardiology, 2009
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976