Can Computer-Aided Design and Computer-Aided Manufacturing Integrating with/without Biomechanical Simulation Improve the Effectiveness of Spinal Braces on Adolescent Idiopathic Scoliosis?
Open Access
Abstract
The CAD/CAM technology has been increasingly popular in manufacturing spinal braces for patients with adolescent idiopathic scoliosis (AIS) in clinics. However, whether the CAD/CAM-manufactured braces or the CAD/CAM-manufactured braces integrating with biomechanical simulation could improve the in-brace correction angle of spinal braces in AIS patients, compared to the manually manufactured braces, has remained unclear. The purpose of this systematic review and meta-analysis was to compare the in-brace correction angle of (1) computer-aided design and computer-aided manufacturing (CAD/CAM)-manufactured braces or (2) the CAD/CAM-manufactured braces integrating with biomechanical simulation with that of (3) manually manufactured braces. The Web of Science, OVID, EBSCO, PUBMED, and Cochrane Library databases were searched for relevant studies published up to March 2023. Five randomized controlled trials (RCTs) or randomized controlled crossover trials were included for qualitative synthesis, and four of them were included for meta-analysis. The meta-analysis effect sizes of the in-brace correction angle for CAD/CAM versus manual method, and CAD/CAM integrating with biomechanical simulation versus the manual method in the thoracic curve group and the thoracolumbar/lumbar curve group were 0.6° (mean difference [MD], 95% confidence intervals [CI]: −1.06° to 2.25°), 1.12° (MD, 95% CI: −8.43° to 10.67°), and 3.96° (MD, 95% CI: 1.16° to 6.76°), respectively. This review identified that the braces manufactured by CAD/CAM integrating with biomechanical simulation did not show sufficient advantages over the manually manufactured braces, and the CAD/CAM-manufactured braces may not be considered as more worthwhile than the manually manufactured braces, based on the in-brace correction angle. More high-quality clinical studies that strictly follow the Scoliosis Research Society (SRS) guidelines with long-term follow-ups are still needed to draw more solid conclusions and recommendations for clinical practice in the future.Keywords
Funding Information
- Tongji Hospital (2017A015/2201102323)
This publication has 59 references indexed in Scilit:
- Could clinical ultrasound improve the fitting of spinal orthosis for the patients with AIS?European Spine Journal, 2012
- 2011 SOSORT guidelines: Orthopaedic and Rehabilitation treatment of idiopathic scoliosis during growthScoliosis and Spinal Disorders, 2012
- Biomechanical evaluation of predictive parameters of progression in adolescent isthmic spondylolisthesis: a computer modeling and simulation studyScoliosis and Spinal Disorders, 2012
- A Biomechanical Study of the Charleston Brace for the Treatment of ScoliosisSpine, 2010
- Computer-aided design and computer-aided manufacture (CAD/CAM) system for construction of spinal orthosis for patients with adolescent idiopathic scoliosisPhysiotherapy Theory and Practice, 2010
- A 3D visualization tool for the design and customization of spinal bracesComputerized Medical Imaging and Graphics, 2007
- Preliminary Evaluation of a Computer-Assisted Tool for the Design and Adjustment of Braces in Idiopathic ScoliosisSpine, 2007
- Virtual prototyping of a brace design for the correction of scoliotic deformitiesMedical & Biological Engineering & Computing, 2007
- Orthoses for Mild Scoliosis: A Prospective Study Comparing Traditional Plaster Mold Manufacturing With Fast, Noncontact, 3-Dimensional AcquisitionSpine, 2005
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002