Abstract
Combined myocardial flow reserve (MFR) by PET and CT coronary angiography (CTA) is a promising tool for assessment of coronary artery disease. Prior analyses of MFR/CTA has been performed as side-by-side interpretation, not as volume rendered, full hybrid analysis, with fused MFR/CTA. We aimed to: (i) establish a method for full hybrid analysis of MFR/CTA, (ii) validate the inter- and intra-observer reproducibility of MFR values, and (iii) determine the diagnostic value of side-by-side versus full hybrid MFR/CTA with 15-O-water PET. Forty-four outpatients scheduled for invasive coronary angiography (ICA) were enrolled prospectively. All underwent rest/stress 15-O-water PET/CTA with ICA as reference. Within two observers of different experience, the Pearson r at global and territorial level exceeded 0.953 for rest, stress, and MFR values, as determined by Carimas software. Within and between observers, the mean differences between rest, stress, and MFR values were close to zero and the confidence intervals for 95% limits of agreement were narrow. The diagnostic performance of full hybrid PET/CTA did not outperform the side-by-side approach, but performed better than MFR without CTA at vessel level: specificity 93% (95% confidence limits: 89–97%) versus 76% (64–88%), p = 0.0004; positive predictive value 71% (55–86%) versus 51% (37–65%), p = 0.0001; accuracy 90% (84–95%) versus 77% (69–84%), p = 0.0009. MFR showed high reproducibility within and between observers of different experience. The full hybrid model was not superior to side-by-side interpretation of MFR/CTA, but proved better than MFR alone at vessel level with regard to specificity, positive predictive value, and accuracy.Keywords
This publication has 34 references indexed in Scilit:
- Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow ReserveJournal of Nuclear Medicine, 2012
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- Cardiac Positron Emission Tomography/Computed Tomography Imaging Accurately Detects Anatomically and Functionally Significant Coronary Artery DiseaseCirculation, 2010
- Definition of Vascular Territories on Myocardial Perfusion Images by Integration with True Coronary Anatomy: A Hybrid PET/CT AnalysisJournal of Nuclear Medicine, 2010
- Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PETJournal of Nuclear Medicine, 2009
- Repeatability of regional myocardial blood flow calculation in 82Rb PET imagingBMC Medical Physics, 2009
- Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical ExperienceJournal of Nuclear Medicine, 2007
- When to use agreement versus reliability measuresJournal of Clinical Epidemiology, 2006
- Quantification of regional myocardial blood flow in vivo with H215O.Circulation, 1984
- Analysis of Probability as an Aid in the Clinical Diagnosis of Coronary-Artery DiseaseNew England Journal of Medicine, 1979