Abstract
To compare patients’ radiation exposure, technical feasibility, imaging quality and complication rate of percutaneous lung biopsies (PLBs) performed with a low-dose (LD) CT protocol under guidance of an optical navigation system. Fifty-two consecutive patients with suspected malignant lung lesions were enrolled and randomised into group 1 (PLBs under the guidance of the navigation system) and group 2 (PLBs under the guidance navigation system with an LD protocol). Patients’ demographics, lesion features, procedure-related variables and CT image quality for group 2 were recorded and compared. Technical success was 100 % in both groups. The radiation dose to patients’ chest was significantly lower in group 2 than in group 1 (group 1: mean TDLP 206 ± 59 mGy·cm, ~ 3.5 ± 1.0 mSv; group 2: 54.2 ± 46.2 mGy·cm, ~ 0.92 ± 0.78 mSv; P < 0.0001). The PNX rate was 12 % in group 1 and 11.1 % in group 2. The haemoptysis rate was 8.0 % in group 1 and 3.7 % in group 2. CT image quality obtained in group 2 was always rated as adequate and as excellent in 15 cases (56.0 %). An optical navigation system with LD CT protocol is useful for performing lung biopsies with decreased patient radiation exposure. • Navigation systems are useful tools in percutaneous imaging-guided procedures. • For lung biopsies, low-dose (LD) CT protocols may be used. • Combining LD protocols with optical CT navigation results in significantly reduced radiation exposure.Keywords
This publication has 20 references indexed in Scilit:
- Percutaneous transthoracic needle biopsy of small (≤1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidanceEuropean Radiology, 2012
- Low-Dose Techniques in CT-guided InterventionsRadioGraphics, 2012
- CT-Guided Percutaneous Biopsy of Intrathoracic LesionsKorean Journal of Radiology, 2012
- Navigation-Based Needle Puncture of a Cadaver Using a Hybrid Tracking Navigational SystemInvestigative Radiology, 2006
- Out-of-Plane Computed-Tomography-Guided Biopsy Using a Magnetic-Field-Based Navigation SystemCardioVascular and Interventional Radiology, 2005
- Navigation with Electromagnetic Tracking for Interventional Radiology Procedures: A Feasibility StudyJournal of Vascular and Interventional Radiology, 2005
- Low-Dose Chest CT: Optimizing Radiation Protection for PatientsAmerican Journal of Roentgenology, 2004
- Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countriesThe Lancet, 2004
- [Pulmonary nodules: dosimetric and clinical studies at low dose multidetector CT].2003
- Lung Cancer Screening: Minimum Tube Current Required for Helical CTRadiology, 2000