Quality of images with toric intraocular lenses
- 1 March 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 44 (3) , 376-381
Abstract
To objectively evaluate the image quality obtained with toric intraocular lenses (IOLs) when misaligned from the intended axis. University Eye Clinic and the Department of Industrial and Information Engineering, University of Trieste, Trieste, Italy. Experimental study. An experimental optoelectronic test bench was created. It consisted of a high-resolution monitor to project target images and an artificial eye. The system simulates the optical and geometric characteristics of the human eye with an implanted toric IOL. A 3.00 diopters corneal astigmatism was simulated. Images reproduced by the optical system were captured according to different IOL axis positions. The quality of each image was analyzed using the visual information fidelity (VIF) criterion. The VIF reduction was calculated at each IOL rotational step. A 5-degree IOL axis rotation from the intended position determined a decay in the image quality of 7.03%. Ten degrees of IOL rotation caused an 11.09% decay of relative VIF value. For a 30-degree rotation, the VIF decay value was 45.85%. Finally, the image decay with no toric correction was 56.70%. The more the objective quality of the image decays progressively, the further the axis of the IOL is rotated from its intended position. The reduction in image quality obtained after 30 degrees of toric IOL rotation was less than 50% and after 45 degrees, the image quality was the same as that of no toric correction.Keywords
This publication has 19 references indexed in Scilit:
- Optical quality of aspheric toric intraocular lenses at different degrees of decenteringGraefe's Archive for Clinical and Experimental Ophthalmology, 2014
- Refractive surprise after toric intraocular lens implantation: Graph analysisJournal of Cataract & Refractive Surgery, 2014
- Prevalence of Corneal Astigmatism before Cataract Surgery in Caucasian PatientsEuropean Journal of Ophthalmology, 2013
- Toric intraocular lenses: Historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complicationsJournal of Cataract & Refractive Surgery, 2013
- Rescue technique for salvaging toric intraocular lens alignmentJournal of Cataract & Refractive Surgery, 2012
- Modulation Transfer Function of a Toric Intraocular Lens: Evaluation of the Changes Produced by Rotation and TiltJournal of Refractive Surgery, 2012
- Residual astigmatism produced by toric intraocular lens rotationJournal of Cataract & Refractive Surgery, 2011
- Foldable toric intraocular lens for astigmatism correction in cataract patientsJournal of Cataract & Refractive Surgery, 2008
- Refractive expectations of patients having cataract surgeryJournal of Cataract & Refractive Surgery, 2005
- Toric intraocular lenses: Correcting astigmatism while controlling axis shiftJournal of Cataract & Refractive Surgery, 1994