Direct sprayed endothelialization, basement membrane and cell junction development on biological and artificial products are highly substrate-dependent and require optimized biofunctionalization
Authors:
- Christian KlopschCKChristian Klopsch
- Marion LudwigMLMarion Ludwig
- Anna SkorskaASAnna Skorska
- Loni ZacherLZLoni Zacher
- Max JerkeMJMax Jerke
- Frank LudererFLFrank Luderer
- Daniela ArbeiterDADaniela Arbeiter
- Niels GrabowNGNiels Grabow
- Thomas MichaelTMThomas Michael
- Ralf GaebelRGRalf Gaebel
- Cornelia LuxCLCornelia Lux
- Petra MelaPMPetra Mela
- 1 January 2015
- journal article
- research article
- Published by Walter de Gruyter GmbH in BioNanoMaterials
- Vol. 16 (4) , 285-299
Abstract
Background: Optimizing endothelialization of medical implants requires deep mechanistic insight into cellular adhesion, cell junction and physiological basement membrane development at the endothelial cell-to-scaffold substrate interface. Methods and results: We employed and standardized endothelial cells and fibrin hydrogel for simultaneous cell-plus-fibrin (EC-Fib) spray application using the Maslanka® spray pen. Quality assessment illustrated excellent structural integrity of EC-Fib. Acellular SynerGraft® showed improved intimal endothelial recellularization after short-term physical and chemical preconditionings including dry-freezing, sodium desoxycholate, Triton-X, acetic acid and collagenase treatments. Artificial substrates poly-L-lactic acid (PLLA), and polyamide-6 (PA-6) were tested regarding their mechanical appropriateness, revealed complete endothelialization following EC-Fib application and showed partially physiological basement membrane development. Additional laminin 1 biofunctionalization on PA-6 moderately enhanced basement membrane gene and protein expression. However, scanning electron microscopy, immunohistology and PCR analyses underlined immature endothelialization, basement membrane and cell junction development on all substrates with clear substrate-dependent differences. Conclusions: Direct sprayed endothelialization outlined the necessity for preconditioning acellular SynerGraft® prostheses for adequate recellularization. Laminin 1 biofunctionalization could slightly improve endothelialization of PA-6 substrates whereas physiological organization of the microenvironment remained immature and seemed highly substrate dependent.Keywords
This publication has 46 references indexed in Scilit:
- Capture of circulatory endothelial progenitor cells and accelerated re-endothelialization of a bio-engineered stent in human ex vivo shunt and rabbit denudation modelEuropean Heart Journal, 2011
- Autologous Valve Replacement—CD133 + Stem Cell-Plus-Fibrin Composite-Based Sprayed Cell Seeding for Intraoperative Heart Valve Tissue EngineeringTissue Engineering Part C: Methods, 2011
- Enhanced Endothelialization on Surface Modified Poly( l -Lactic Acid) SubstratesTissue Engineering Part A, 2011
- Impact of scaffold micro and macro architecture on Schwann cell proliferation under dynamic conditions in a rotating wall vessel bioreactorMaterials Science and Engineering: C, 2011
- Designing a three-dimensional alginate hydrogel by spraying method for cartilage tissue engineeringSoft Matter, 2010
- The Emerging Role of Valve Interstitial Cell Phenotypes in Regulating Heart Valve PathobiologyThe American Journal of Pathology, 2007
- Histopathologic Findings in a Novel Decellularized Pulmonary Homograft: An Autopsy StudyThe Annals of Thoracic Surgery, 2005
- The independent role of cyclic flexure in the early in vitro development of an engineered heart valve tissueBiomaterials, 2005
- Biodegradation of the Copolymeric Polylactide StentJournal of Vascular Research, 2001
- Mechanics of native bovine pericardiumBiomaterials, 1994