Modelling the elastic scattering in diagnostic radiology: the importance of structure form factors
Authors:
- O D Gon AlvesOAO D Gon Alves
- H SchechterHSH Schechter
- J EichlerJEJ Eichler
- 17 June 2003
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (13) , 1907-1916
Abstract
The importance of structure form factors in describing elastic scattering in diagnostic radiology was studied through a Monte Carlo code built to reproduce scattering in large water samples. The code, developed by us, considers all relevant interactions, including multiple scattering and interference due to scattering by the liquid structure. Geometrical conditions and energies similar to those found in radiology were used. The secondary to primary radiation ratio using the usual free atom approximation and the structure form factor was obtained and both approaches were compared. Calculations of radiological parameters such as the angular distribution of photons incident on the detector and the fraction of scattered photons stopped by anti-scattering grids were also performed considering mammography, thorax and abdomen radiography conditions. The results have shown that S(beta)/P depends on the experimental set-up, being more important for low momentum transfers and sample sizes for which the multiple scattering is not expected to be significant, as in the case of mammography. It was also verified that large samples increase the probability of multiple scattering, masking the structure peak in S(beta) and making the sample structure important just for relatively thin samples. Considering mammography-like geometry, the maximum of the S(beta)/P distribution considering structure form factors occurs around 15 degrees while the correspondent maximum without considering the structure factors occurs around 10 degrees for any sample thickness. S(beta)/P is almost independent of the irradiation field, with the maximum remaining at 15 degrees and 10 degrees for the SFF and FAFF, respectively. The cases studied in this paper stress some conditions in which it is mandatory to use SFF, but since it requires no further significant efforts, the SFF approach is recommended as a standard procedure when describing the elastic scattering process in radiology.Keywords
This publication has 14 references indexed in Scilit:
- X-ray scattering from human breast tissues and breast-equivalent materialsPhysics in Medicine & Biology, 2001
- Monte Carlo simulation of diagnostic x‐ray scatterMedical Physics, 1988
- Some properties of photon scattering in water phantoms in diagnostic radiologyMedical Physics, 1986
- Calculation of the small-angle distribution of scattered photons in diagnostic radiology using a Monte Carlo collision density estimatorMedical Physics, 1986
- Coherent scatter in diagnostic radiologyMedical Physics, 1983
- Molecular Form Factors and Photon Coherent Scattering Cross Sections of WaterJournal of Physical and Chemical Reference Data, 1982
- Scattered radiation in fan beam imaging systemsMedical Physics, 1982
- Monte Carlo calculations of X-ray scatter data for diagnostic radiologyPhysics in Medicine & Biology, 1981
- Rayleigh scattering by neutral atoms, 100 eV to 10 MeVPhysical Review A, 1980
- Atomic form factors, incoherent scattering functions, and photon scattering cross sectionsJournal of Physical and Chemical Reference Data, 1975