Revealing heterogeneity in correlation times of EGFP encapsulated in complex coacervate core micelles by analysis of fluorescence anisotropies
- 24 August 2022
- journal article
- research article
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 10 (4) , 045006
Abstract
Encapsulation of enhanced green fluorescent protein (EGFP) in complex coacervate core micelles (C3Ms) can be established by mixing EGFP with diblock polymers at equal charge ratio. It has previously been shown that this encapsulation system is highly dynamic, implying existence of different populations; GFP free in solution or complexed with polymers (small complexes) and EGFP encapsulated in C3Ms. We performed time resolved fluorescence anisotropy experiments to determine the relative populations of EGFP encapsulated in C3Ms using three different fluorescence anisotropy decay analysis methods. First, Maximum Entropy Method (MEM) data analysis was employed for five different EGFP concentrations in C3Ms that were mixed with dark fluorescent proteins (10, 20, 30, 40 and 50% EGFP, respectively). In all cases, correlation-time distributions between 0.1 and 100 ns (on a logarithmic timescale) are clearly visible showing bimodal distribution. The distribution between 0.1 and 2.0 ns is due to homo-FRET between EGFP molecules packed in micelles and the distribution between 8 and 30 ns coincides with the correlation-time distribution of free EGFP in solution. The fraction of homo-FRET distribution linearly increases with increase of relative micellar EGFP concentrations. These MEM results were corroborated by two different analysis methods: global population analysis of all five fluorescence anisotropy decays arising from EGFP in micelles together with the one of free EGFP (direct analysis of anisotropies) and global associative population analysis of anisotropies by fitting parallel and perpendicular fluorescence decay components. In contrast to global analyses approaches, the MEM method directly reveals distributions of correlation times without any prior information about the sample. However, global associative analysis of anisotropies by fitting parallel and perpendicular fluorescence decay components is the only method that allows to estimate accurately fractions of free fluorophores in solution and encapsulated fluorophores.Keywords
This publication has 27 references indexed in Scilit:
- Encapsulation of GFP in Complex Coacervate Core MicellesBiomacromolecules, 2015
- FRET-FLIM applications in plant systemsProtoplasma, 2014
- Global Analysis of Autocorrelation Functions and Photon Counting Distributions in Fluorescence Fluctuation Spectroscopy2013
- Global Analysis of Time-Resolved Fluorescence Data2013
- Green-Fluorescent Protein from the Bioluminescent Jellyfish Clytia gregaria Is an Obligate Dimer and Does Not Form a Stable Complex with the Ca2+-Discharged Photoprotein ClytinBiochemistry, 2011
- Homo‐FRET Imaging as a Tool to Quantify Protein and Lipid ClusteringChemphyschem, 2010
- Reversibility and Relaxation Behavior of Polyelectrolyte Complex Micelle FormationThe Journal of Physical Chemistry B, 2009
- Complex coacervate core micellesAdvances in Colloid and Interface Science, 2009
- Effects of Refractive Index and Viscosity on Fluorescence and Anisotropy Decays of Enhanced Cyan and Yellow Fluorescent ProteinsJournal of Fluorescence, 2005
- Green Fluorescent Protein (GFP): Applications, Structure, and Related Photophysical BehaviorChemical Reviews, 2002