Polysomnographic Endotyping to Select Patients with Obstructive Sleep Apnea for Oral Appliances
- 1 November 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 16 (11) , 1422-1431
Abstract
Rationale: Oral appliance therapy is efficacious in many patients with obstructive sleep apnea (OSA), but prediction of treatment outcome is challenging. Small, detailed physiological studies have identified key OSA endotypic traits (pharyngeal collapsibility and loop gain) as determinants of greater oral appliance efficacy. Objectives: We used a clinically applicable method to estimate OSA traits from routine polysomnography and identify an endotype-based subgroup of patients expected to show superior efficacy. Methods: In 93 patients (baseline apnea–hypopnea index [AHI], ≥20 events/h), we examined whether polysomnography-estimated OSA traits (pharyngeal: collapsibility and muscle compensation; nonpharyngeal: loop gain, arousal threshold, and ventilatory response to arousal) were associated with oral appliance efficacy (percentage reduction in AHI from baseline) and could predict responses to treatment. Multivariable regression (with interactions) defined endotype-based subgroups of “predicted” responders and nonresponders (based on 50% reduction in AHI). Treatment efficacy was compared between the predicted subgroups (with cross-validation). Results: Greater oral appliance efficacy was associated with favorable nonpharyngeal traits (lower loop gain, higher arousal threshold, and lower response to arousal), moderate (nonmild, nonsevere) pharyngeal collapsibility, and weaker muscle compensation (overall R 2 = 0.30; adjusted R 2 = 0.19; P = 0.003). Predicted responders (n = 54), compared with predicted nonresponders (n = 39), exhibited a greater reduction in AHI from baseline (mean [95% confidence interval], 73% [66–79] vs. 51% [38–61]; P < 0.0001) and a lower treatment AHI (8 [6–11] vs. 16 [12–20] events/h; P = 0.002). Differences persisted after adjusting for clinical covariates (including baseline AHI, body mass index, and neck circumference). Conclusions: Quantifying OSA traits using clinical polysomnography can identify an endotype-based subgroup of patients that is highly responsive to oral appliance therapy. Prospective validation is warranted.Keywords
This publication has 46 references indexed in Scilit:
- A simplified method for determining phenotypic traits in patients with obstructive sleep apneaJournal of Applied Physiology, 2013
- Rules for Scoring Respiratory Events in Sleep: Update of the 2007 AASM Manual for the Scoring of Sleep and Associated EventsJournal of Clinical Sleep Medicine, 2012
- Effects of treatment with oral appliance on 24-h blood pressure in patients with obstructive sleep apnea and hypertension: a randomized clinical trialSleep and Breathing, 2012
- Mandibular advancement appliances remain effective in lowering respiratory disturbance index for 2.5–4.5 yearsSleep Medicine, 2011
- A method for measuring and modeling the physiological traits causing obstructive sleep apneaJournal of Applied Physiology, 2011
- Eszopiclone increases the respiratory arousal threshold and lowers the apnoea/hypopnoea index in obstructive sleep apnoea patients with a low arousal thresholdClinical Science, 2011
- Mandibular advancement appliance for obstructive sleep apnoea: results of a randomised placebo controlled trial using parallel group designJournal of Sleep Research, 2008
- Prospective evaluation of an oral appliance in the treatment of obstructive sleep apnea syndromeSleep and Breathing, 2005
- A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea TreatmentAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Determination of the best significance level in forward stepwise logistic regressionCommunications in Statistics - Simulation and Computation, 1997