SU-8 micromachining of millimeter and submillimeter waveguide circuits
Authors:
- 1 June 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 0149645X,p. 961-964
Abstract
Micromachined WR 3.4 waveguide circuits are fabricated using a SU-8 micromachining process. In order to demonstrate the viability and repeatability of this process both straight waveguide sections and cylindrical cavity resonators are fabricated and measured. The SU-8 waveguide compares reasonably well to a standard WR 3.4 waveguide section. The measured cavity resonators demonstrate quality factors of 1900 and 2200 at a resonant frequency of 308 GHz.Keywords
This publication has 6 references indexed in Scilit:
- SU-8 micromachining process for millimeter and submillimeter-wave waveguide circuit fabrication2008
- Silicon Micromachined W-Band Folded and Straight Waveguides Using DRIE Technique2006
- Development of a Multi-layer SU-8 Process for Terahertz Frequency Waveguide Blocks2005
- Fabrication of a superconducting hot-electron bolometer receiver with micromachined waveguide components2002
- A new micro-machined millimeter-wave and terahertz snap-together rectangular waveguide technologyIEEE Microwave and Guided Wave Letters, 1999
- Measurement of resonant frequency and quality factor of microwave resonators: Comparison of methodsJournal of Applied Physics, 1998