Factors Associated with the Treatment Costs within the First Year after Pacemaker Implantation or Pulse Generator Replacement
Open Access
- 1 January 2024
- journal article
- research article
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 121 (4)
Abstract
Background The use of artificial cardiac pacemakers has grown steadily in line with the aging population. Objectives To determine the rates of hospital readmissions and complications after pacemaker implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS). Methods A prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%. Results A total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost. Conclusions The results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.Keywords
This publication has 20 references indexed in Scilit:
- The Impact of Charlson Comorbidity Index on De Novo Cardiac Implantable Electronic Device Procedural Outcomes in the United StatesMayo Clinic Proceedings, 2022
- Trends in Cardiovascular Implantable Electronic Device Insertion Between 1988 and 2018 in Olmsted CountyJACC: Clinical Electrophysiology, 2021
- Prognosis after pacemaker implantation in extreme elderlyEuropean Journal of Internal Medicine, 2019
- Thirty-day readmissions after cardiac implantable electronic devices in the United States: Insights from the Nationwide Readmissions DatabaseHeart Rhythm, 2018
- Complications and Health Care Costs Associated With Transvenous Cardiac Pacemakers in a Nationwide AssessmentJACC: Clinical Electrophysiology, 2017
- P1353Etiologies and predictors for 30-day readmission after pacemaker placement for atrioventricular block. A nationwide analysisEuropean Heart Journal, 2017
- Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in DenmarkEuropean Heart Journal, 2013
- Cost-of-illness study of patients subjected to cardiac rhythm management devices implantation: results from a single tertiary centreEP Europace, 2012
- Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE studyHeart Rhythm, 2012
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009