Wear in the Prosthetic Shoulder: Association With Design Parameters
- 4 October 2006
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 129 (2) , 223-230
Abstract
Total replacement of the glenohumeral joint provides an effective means for treating a variety of pathologies of the shoulder. However, several studies indicate that the procedure has not yet been entirely optimized. Loosening of the glenoid component remains the most likely cause of implant failure, and generally this is believed to stem from either mechanical failure of the fixation in response to high tensile stresses, or through osteolysis of the surrounding bone stock in response to particulate wear debris. Many computational studies have considered the potential for the former, although only few have attempted to tackle the latter. Using finite-element analysis an investigation, taking into account contact pressures as well as glenohumeral kinematics, has thus been conducted, to assess the potential for polyethylene wear within the artificial shoulder. The relationships between three different aspects of glenohumeral design and the potential for wear have been considered, these being conformity, polyethylene thickness, and fixation type. The results of the current study indicate that the use of conforming designs are likely to produce slightly elevated amounts of wear debris particles when compared with less conforming joints, but that the latter would be more likely to cause material failure of the polyethylene. The volume of wear debris predicted was highly influenced by the rate of loading, however qualitatively it was found that wear predictions were not influenced by the use of different polyethylene thicknesses nor fixation type while the depth of wearing was. With the thinnest polyethylene designs the maximum depth of the wear scar was seen to be upwards of 20% higher with a metal-backed fixation as opposed to a cemented design. In all-polyethylene designs peak polymethyl methacrylate tensile stresses were seen to reduce with increasing polyethylene thickness. Irrespective of the rate of loading of the shoulder joint, the current study indicates that it is possible to optimize glenoid component design against abrasive wear through the use of high conformity designs, possessing a polyethylene thickness of at least .
Keywords
This publication has 39 references indexed in Scilit:
- The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2004
- Retrieved glenoid components: A classification system for surface damage analysisThe Journal of Arthroplasty, 2002
- Implant retrieval studies of the wear and loosening of prosthetic joints: a reviewWear, 2000
- Glenohumeral contact forcesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: A review of key influencesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Three-Dimensional Finite Element Analysis of Glenoid Replacement Prostheses: A Comparison of Keeled and Pegged Anchorage SystemsJournal of Biomechanical Engineering, 2000
- Biological reactions to wear debris in total joint replacementProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Wear in retrieved condylar knee arthroplastiesThe Journal of Arthroplasty, 1997
- Biological reaction to debris in relation to joint prosthesesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Factors contributing to the wear of polyethylene in clinical practiceProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997