Time-Resolved Measurements of Indoor Chemical Emissions, Deposition, and Reactions in a University Art Museum
Top Cited Papers
Open Access
- 16 April 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 53 (9) , 4794-4802
Abstract
A six-week study was conducted at the University of Colorado Art Museum during which volatile organic compounds (VOCs), CO2, O3, NO, NO2, other trace gases, and submicron aerosol were measured continuously. These measurements were then analyzed using a box model to quantify the rates of major processes that transformed the composition of the air. VOC emission factors were quantified for museum occupants and their activities. Deposition of VOCs to surfaces was quantified across a range of VOC saturation vapor concentrations (C*) and Henry’s law constants (H) and was determined to be a major sink for VOCs with C* < 108 μg m-3 and H > 102 M atm-1. Reaction rates of VOCs with O3, OH radicals, and NO3 radicals were quantified, with unsaturated and saturated VOCs having oxidation lifetimes of >5 and >15 h, making deposition to surfaces and ventilation the dominant VOC sinks in the museum. Ozone loss rates were quantified inside a museum gallery, where reactions with surfaces, NO, occupants, and NO2 accounted for 62%, 31%, 5%, and 2% of the O3 sink. The measured concentrations of acetic acid, formic acid, NO2, O3, particulate matter, SO2, and total VOCs were below the guidelines for museums.Keywords
Funding Information
- Alfred P. Sloan Foundation (G-2016-7173)
This publication has 50 references indexed in Scilit:
- Volatile Organic Compound Emissions from Humans IndoorsEnvironmental Science & Technology, 2016
- Contribution of human-related sources to indoor volatile organic compounds in a university classroomIndoor Air, 2015
- Chemistry in indoor environments: 20 years of researchIndoor Air, 2011
- Indoor environment and conservation in the Royal Museum of Fine Arts, Antwerp, BelgiumJournal of Cultural Heritage, 2004
- Indoor air quality at the Correr Museum, Venice, ItalyScience of The Total Environment, 1999
- The Indoor Environment of a Modern Museum Building, The Sainsbury Centre for Visual Arts, Norwich, UKIndoor Air, 1999
- Protecting museum collections from soiling due to the deposition of airborne particlesAtmospheric Environment. Part A. General Topics, 1991
- Nitric acid concentrations in southern California museumsEnvironmental Science & Technology, 1990
- The measurement and model predictions of indoor ozone concentrations in museumsAtmospheric Environment. Part A. General Topics, 1990
- Concentration and fate of airborne particles in museumsEnvironmental Science & Technology, 1990