TG-Field: Geometry-Aware Radiative Gaussian Fields for Tomographic Reconstruction
Preprint
Abstract
3D Gaussian Splatting (3DGS) has revolutionized 3D scene representation with superior efficiency and quality. While recent adaptations for computed tomography (CT) show promise, they struggle with severe artifacts under highly sparse-view projections and dynamic motions. To address these challenges, we propose Tomographic Geometry Field (TG-Field), a geometry-aware Gaussian deformation framework tailored for both static and dynamic CT reconstruction. A multi-resolution hash encoder is employed to capture local spatial priors, regularizing primitive parameters under ultra-sparse settings. We further extend the framework to dynamic reconstruction by introducing time-conditioned representations and a spatiotemporal attention block to adaptively aggregate features, thereby resolving spatiotemporal ambiguities and enforcing temporal coherence. In addition, a motion-flow network models fine-grained respiratory motion to track local anatomical deformations. Extensive experiments on synthetic and real-world datasets demonstrate that TG-Field consistently outperforms existing methods, achieving state-of-the-art reconstruction accuracy under highly sparse-view conditions.Keywords
All Related Versions
This publication has 17 references indexed in Scilit:
- NeRP: Implicit Neural Representation Learning With Prior Embedding for Sparsely Sampled Image ReconstructionIEEE Transactions on Neural Networks and Learning Systems, 2022
- NeRF: Representing Scenes as Neural Radiance Fields for View Synthesis2020
- SPARE: Sparse‐view reconstruction challenge for 4D cone‐beam CT from a 1‐min scanMedical Physics, 2019
- A longitudinal four‐dimensional computed tomography and cone beam computed tomography dataset for image‐guided radiation therapy research in lung cancerMedical Physics, 2016
- TIGRE: a MATLAB-GPU toolbox for CBCT image reconstructionBiomedical Physics & Engineering Express, 2016
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- Realistic CT simulation using the 4D XCAT phantomMedical Physics, 2008
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- On the determination of functions from their integral values along certain manifoldsIEEE Transactions on Medical Imaging, 1986
- Representation of a Function by Its Line Integrals, with Some Radiological ApplicationsJournal of Applied Physics, 1963