Evaluation of the diagnostic value of a computed radiography system by comparison of digital hard copy images with screen–film mammography: results of a prospective clinical trial
- 2 March 2006
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 16 (6) , 1360-1366
Abstract
The purpose of the study was to determine prospectively the diagnostic value of a computed radiography (CR) system by comparing mammographic hard copy images with screen–film mammography (SFM). A series of 100 patients, who came for diagnostic investigation, underwent two-view SFM (Lorad M-IV Platinum) and digital mammography with a CR system (AGFA CR system). The images were obtained by double exposure, i.e. same view without removing compression of the corresponding breast. The CR images were processed with dedicated processing for mammography. Six radiologists read sets of SFM and CR images. The primary efficacy parameter was the overall diagnostic value. The secondary efficacy parameters were lesion conspicuity and lesion details (for masses and micro-calcifications), tissue visibility at chest wall and at skin line, axillary details, overall density and sharpness impression and the overall noise impression. These parameters were scored by a 7-point scoring system. “CR non-inferior to SFM” was concluded if the lower confidence interval bound exceeded 80%. The confidence interval for the overall diagnostic value was between 96.4% and 100%. Pooled analysis of the ten features for image quality comparison demonstrated for all but one feature (lesion details of the calcifications) CR non-inferiority to SFM.Keywords
This publication has 11 references indexed in Scilit:
- Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer ScreeningNew England Journal of Medicine, 2005
- Digital detectors for mammography: the technical challengesEuropean Radiology, 2004
- Screen-Film Mammography versus Full-Field Digital Mammography with Soft-Copy Reading: Randomized Trial in a Population-based Screening Program—The Oslo II StudyRadiology, 2004
- The current status of digital mammographyClinical Radiology, 2004
- Population-based Mammography Screening: Comparison of Screen-Film and Full-Field Digital Mammography with Soft-Copy Reading—Oslo I StudyRadiology, 2003
- Diagnostic Accuracy of Digital Mammography in Patients with Dense Breasts Who Underwent Problem-solving Mammography: Effects of Image Processing and Lesion TypeRadiology, 2003
- Screen film vs full-field digital mammography: image quality, detectability and characterization of lesionsEuropean Radiology, 2002
- Comparison of Full-Field Digital Mammography with Screen-Film Mammography for Cancer Detection: Results of 4,945 Paired ExaminationsRadiology, 2001
- Image Processing Algorithms for Digital Mammography: A Pictorial EssayRadioGraphics, 2000
- Multiscale image contrast amplification (MUSICA)1994